... in your data center use an SLC™ 8000 advanced console server integrated with ConsoleFlow™ centralized management software. Give users the option not to go to site.
Security is paramount, the SLC 8000 console server is FIPS 140-2 certified and provides remote console access for up 48 ports. This will significantly reduce the timeto-resolution for solving problems, cutting out the...
Data Center Solution Brief - Page 3
... in your data center use an SLC™ 8000 advanced console server integrated with ConsoleFlow™ centralized management software. Give users the option not to go to site.
Security is paramount, the SLC 8000 console server is FIPS 140-2 certified and provides remote console access for up 48 ports. This will significantly reduce the timeto-resolution for solving problems, cutting out the...
IO Module Install Guide - Page 1
... AT A STATICFREE WORKPLACE.
THE USB I/O MODULE F/W (FRUSB1601) REQUIRES
SLC 8000 FIRMWARE 7.2 OR ABOVE. DOWNLOAD THE LATEST VERSION AT:
www.lantronix.com/ support/downloads
WHAT'S IN THE BOX
Installation Guide INSTALL GUIDE
SLC 8000 I/O Module
Module Extractor
RJ45 Loopback Cable
Only for RJ45 I/O Module
1. Shut down the SLC 8000 either via the Web Manager or the Command Line Interface and...
IO Module Install Guide - Page 2
... installed I/O modules under I/O Module Type(s).
show sysstatus Note: Using this command also allows you to check how many device ports are detected and what the status of each one is.
!
Thank you for choosing Lantronix. Please register this product in order to receive notifications for firmware and documentation updates at www.lantronix.com/product-registration.
Contact Technical Support...
User Guide - Page 4
... upgraded SNMP v3 SHA2 support expanded support for HSPA+ gateway integration
March 2019
N Updated for firmware release 7.8.0.0.
Added support for custom Expect scripts that can be connected to the SLC CLI or a device port.
April 2019
P Updated for firmware release 7.9.0.0. Added support for custom Python and Tcl scripts.
SLC™ 8000 Advanced Console Manager...
User Guide - Page 5
... support for exporting the current SLC configuration as a text file Added 'set snmp trapenable' CLI command Added audit log messages option for ConsoleFlow client Added AES192 and AES256 options to SNMP v3 encryption Moved SNMP parameters under Services commands to SNMP commands Updated CLI syntax
SLC™ 8000 Advanced Console Manager User Guide...
User Guide - Page 21
... features, and the protocols they support.
Chapter 3: Installation
Provides technical specifications; describes connection form factors and power supplies; provides instructions for installing the SLC 8000 advanced console manager in a rack.
Chapter 4: Quick Setup
Provides instructions for getting your SLC unit up and running and for configuring required settings.
Chapter 5: Web and Command...
User Guide - Page 26
...
The SLC 8000 firmware has the following basic capabilities: Software reversible device port pinouts (serial RJ45 ports only) Connects up to 48 RS-232 serial consoles or up to 48 USB consoles Support use of simple straight-through cables for use with Cisco, Sun and other devices that
use the "Cisco" RJ-45 serial pinouts 10/100/1000 Base-T Ethernet network...
User Guide - Page 48
... Battery Replacement Instructions Warning: RISK OF ELECTRICAL SHOCKS; DISCONNECT ALL POWER AND
PHONE LINE BEFORE SERVICING! You will need a medium size Phillips screw driver. 1. Turn off power to the SLC 8000 advanced console manager. 2. Locate the battery/modem door on the top of the SLC unit. 3. Carefully unscrew and lift the door off with the screw driver.
4. If there is a modem installed, note...
User Guide - Page 81
...of the fail-over device (the minimum required firmware version for HSPA+ is 8.1.0.0, Sierra Wireless ES450 is 4.9.2, and for Lantronix G52x Series (G52x) gateway is 1.8.0.0). For the HSPA+ gateway, if the firmware is updated and new items are added to the status output by the gateway, the new items will automatically be displayed on the SLC.
SLC™ 8000 Advanced Console Manager User Guide
81
User Guide - Page 84
... must be specified.
Note: Connections available depend on the model of the SLC unit.
Load Cellular Gateway Firmware Options
USB Port
FTP/SFTP/SCP Server
Path Login Password/ Retype Password
Select the USB port. The firmware files must be stored in the top level directory of the USB flash drive.
Enter the IP address or host name of the server used for obtaining the...
User Guide - Page 163
... from the ConsoleFlow server to perform actions, such as reboot or shutdown. Each time a message is received, Status of Client will display Message received with the date and time the message was received.
4. Firmware and Configuration Updates
The client checks for firmware and configuration updates at the interval defined by Interval
SLC™ 8000 Advanced Console Manager User Guide
163
User Guide - Page 164
... a response to the newline character within approximately one second, and this may result in the Managed Device Connection Status being set to Disconnected.
8. CLI Commands
CLI commands can be issued to a set of console managers from ConsoleFlow. CLI commands which require user input for a confirmation or prompt, or require some other user
SLC™ 8000 Advanced Console Manager User Guide
164
User Guide - Page 167
... of the Eth1 MAC address appended.
Long description that is displayed in the ConsoleFlow server UI.
The unique device identifier. The ID is 32 alphanumeric characters. The ID may be provisioned using Lantronix Provisioning Manager (LPM). Contact Lantronix Tech Support for more information on LPM.
View-only field. Displays the serial number.
SLC™ 8000 Advanced Console Manager User Guide
167
User Guide - Page 171
...and manage files on the selected USB thumb drive or SD Card. Files on the storage device may then be deleted, downloaded or renamed. See the next section for more information.
Manage Files on Storage Device
To manage files, perform the following steps. 1. Click the Manage Files on the Storage Device link on the Enter the following fields. page.
SLC™ 8000 Advanced Console Manager User Guide...
User Guide - Page 222
... Right to obtain diagnostic information and reports about the unit.
Right to upgrade the firmware on the unit and save or restore a configuration (all settings). Selecting this option automatically selects Reboot & Shutdown. Right to configure internal modem settings. Right to control device ports.
Right to enter device port configurations.
SLC™ 8000 Advanced Console Manager User Guide
222
User Guide - Page 261
..., which will interrupt the power provided by the RPM. Some PDUs and UPSes have a default delay that they will wait before initiating a shutdown; this setting may be visible in the raw data (see above) as "ups.delay.shutdown".
Deletes the selected RPM, after a confirmation.
Figure 10-2 RPM Shutdown Order
SLC™ 8000 Advanced Console Manager User Guide
261
User Guide - Page 289
... Web Access Diagnostics & Reports Firmware & Configuration Internal Modem Device Port Operations Device Port Configuration USB SD Card RPM
Right to add, update, and delete all editable fields. Right to enter Network settings. Right to enable and disable system logging, SSH and Telnet logins, SNMP, and SMTP. Right to view and manage Secure Lantronix units (e.g., Spider, or SLC units) on the local...
User Guide - Page 293
... update internal modem settings. Right to control device ports.
Right to enter device port settings.
Right to enter modem settings for USB devices and control USB storage devices. Right to enter settings for SD card. Right to manage and control remote power managers.
5. Click the Apply button.
Note: You must reboot the unit before your changes will take effect.
SLC™ 8000 Advanced Console...
User Guide - Page 396
... Enable or disable firmware and configuration updates via ConsoleFlow.
set cflow rebootafterupdate
Syntax set cflow rebootafterupdate Description Enable or disable reboots after firmware or configuration updates.
set cflow allowremoteconnection
Syntax set cflow allowremoteconnection Description Enable or disable remote connections.
SLC™ 8000 Advanced Console Manager User Guide