Intel P4000M driver and firmware
Related Intel P4000M Manual Pages
Download the free PDF manual for Intel P4000M and other Intel manuals at ManualOwl.com
Technical Product Specification - Page 4
... Mechanical Overview 61 AC Input Requirements 63 Efficiency ...65 DC Output Specification 66 Protection Circuits 69 Control and Indicator Functions 70 Thermal CLST...72 Power Supply Diagnostic "Black Box 72 Firmware Update 73 Lower Current Common Redundant Power Distribution Board (PDB 73 Mechanical Overview 74 DC/DC converter cooling 75 DC Output Specification 75 Protection Circuits...
Technical Product Specification - Page 15
... Chassis P4000M Family Design Features
The Intel® Server Chassis P4000M Family make extensive use of tool-less hardware features and, depending on configuration and upgrade features, provides redundant power supply, redundant cooling and hot swappable hard drives capability. Three 5.25-inch half-height peripheral bays are available for the installation of a floppy drive, CD-ROM drive, and...
Technical Product Specification - Page 62
Chassis Power Sub-system
Intel® Server Chassis P4000M Family TPS
Refer to the Intel "Common Hardware & Firmware Requirements for CRPS Power Supplier" for detailed requirements.
2.2.9 Firmware Uploader The power supply has the capability to update its firmware from the PMBus* interface while it is in standby mode. This FW can be updated when in the system and in standby mode and...
Technical Product Specification - Page 75
...into nonvolatile memory when a critical event shuts down the power supply. This data shall be accessible from the SMBus* interface with an external source providing power to the 12Vstby output.
Refer to Intel® Common Hardware & Firmware Requirements for CRPS Power Supplier for detailed requirements.
2.3.9 Firmware Uploader
The power supply shall have the capability to update its firmware from...
Technical Product Specification - Page 87
... FW can be updated when in the system and in standby mode and outside the system with power applied to the 12Vstby pins. Refer to the Intel® Common Hardware & Firmware Requirements for CRPS Power Supplier for detailed requirements.
2.5
Lower Current Common Redundant Power Distribution Board (PDB)
The Power Distribution Board (PDB) for Intel® Server Chassis P4000M supports the Common...
Technical Product Specification - Page 118
... Plane (HSBP)
Intel® Server Chassis P4000M Family TPS
5. Hot-Swap Back Plane (HSBP)
5.1 4U 4x3.5" Hot-Swap Back Plane (HSBP)
5.1.1 Overview The Chassis supports 4x3.5" SAS/SATA backplane. The backplane provide the platform support for up to four hot-swap SAS or SATA hard drives.
5.1.1.1
Key Features
The 4HDD 3.5" SAS/SATA HSBP supports the following feature set:
4x...
Technical Product Specification - Page 124
...; SGPIO cable - 5pin on HSBP side to 5pin on host controller side.
5.2 4U 8x3.5" Hot-Swap Back Plane (HSBP)
5.2.1 Overview The chassis supports 8x3.5" SAS/SATA backplane. The backplane provide the platform support for up to eight hot-swap SAS or SATA hard drives.
5.2.1.1
Key Features
The 8HDD 3.5" SAS/SATA HSBP supports the following feature set:
8x SAS/SATA 3.5" hot...
Technical Product Specification - Page 130
... 2.5" SAS/SATA HSBP supports the following feature set:
8x SAS/SATA 2.5" hot swap hard drives. Two SGPIO SFF-8485 interfaces in sideband of mini-SAS connectors. One I2C interface from a 5pin connector for HDD status communication to BMC over
slave SMB bus. Temperature sensor and FRU support. In-application FW updateable over I2C...
Technical Product Specification - Page 136
... with different cables setting.
6.1.1 Front Panel Cable A 24-conductor ribbon cable with 24-pin IDC connectors links the front panel to the SSI EEB Revision 3.61-compliant server board.
Figure 58. Chassis Front Panel Cable
6.1.2 Intrusion Switch cable The intrusion switch cable acts as a switch installed on the chassis for chassis intrusion detection, allowing server management software to detect...
Technical Product Specification - Page 149
...
Function
Conditions/Stress Software Windows-2k8R2 Idling IO meter + PTU_1.5 (Core 50%) IO meter + PTU_1.5 (Core & Memory 50%)
9.3.1.2
Test Environment
The room temperature shall be 23°C+/-2°C, recommend related humidity is 40% ~70% based on ISO-7779 standard.
9.3.1.3
Declared Acoustic Data
Table 180. System Configurations
Chassis Motherboard CPU TDP Memory PCI card HDD
Stress...
Technical Product Specification - Page 150
.../Stress Software Windows-2k8R2 Idling IO meter + PTU_1.5 (Core 50%) IO meter + PTU_1.5 (Core & Memory 50%) IO meter + GPGPU CV utility
9.3.2.2
Test Environment
The room temperature shall be 23°C+/-2°C, recommend related humidity is 40% ~70% based on ISO-7779 standard.
9.3.2.3
Declared Acoustic Data
Table 183. System Configurations
Chassis Motherboard CPU TDP Memory PCI card HDD...
Technical Product Specification - Page 153
....
The Intel® Local Control Panel can only be used with systems configured with an Intel® Management Module.
Make sure the latest system software is loaded on the server. This includes system BIOS, FRU/SDR, BMC firmware, and hot-swap controller firmware. The latest system software can be downloaded from http://www.intel.com/support/motherboards/server/.
Revision 1.1
Intel order number...
P4000M family Service Guide - Page 5
...174; Server Chassis P4000M Family Technical Product Specification See the section on the web page titled, "Document and Guides". Intel® Server Chassis P4000M Family Quick Installation User's Guide Spares and Configuration Guide Intel® Server Configurator tool
Power Budget Tool Intel® Server Management Software Firmware and Drivers
Intel® Server Chassis P4000M Service Guide
v
P4000M family Service Guide - Page 6
... Hard Drive(s 25
Removing and Installing 4x3.5" Hot-swap Hard Drive Cage Assembly 27 Removing 4x3.5" Hot-swap Hard Drive Cage with Backplane 27 Installing 4x3.5'' Hot-swap Hard Drive Cage with Backplane 28
Removing and Installing 4x3.5'' Hot-swap Backplane 30 Removing 4x3.5'' Hot-swap Backplane 30 Installing 4x3.5" Hot-swap Backplane 31
vi
Intel® Server Chassis P4000M Service Guide
P4000M family Service Guide - Page 28
Hardware Installations and Upgrades
2
Hardware Installations and Upgrades
Before You Begin
Before working with your server product, pay close attention to the "Appendix B: Safety Information" This document provides instructions for adding and replacing chassis components. For instructions on replacing components on the server board, such as the processor and memory DIMMs, see the instructions ...
P4000M family Service Guide - Page 45
... Installations and Upgrades
10. Install the chassis cover. For instructions, see "Installing the Chassis Cover". 11. Plug all peripheral devices and the AC power cable into the server. 12. Power up the server.
Removing and Installing 8x3.5'' Hot-swap Hard Drive Cage Assembly
NOTE
This procedure applies only to the Intel® Server Chassis P4000M family with 8x3.5'' hot-swap hard disk drive...
P4000M family Service Guide - Page 47
... instructions, see "Installing the Airduct". 9. Install the chassis cover. For instructions, see "Installing the Chassis Cover". 10. Plug all peripheral devices and the AC power cable into the server. 11. Power up the server.
Removing and Installing 8x3.5'' Hot-swap Backplane
NOTE
This procedure applies only to the Intel® Server Chassis P4000M family with 8x3.5'' hot-swap hard disk drive cage...
P4000M family Service Guide - Page 84
Hardware Installations and Upgrades
9. Install the front bezel. For instructions, see "Removing and Installing the Front Bezel". 10. Install the air duct based on board requirement. 11. Install the chassis cover. For instructions, see "Installing the Chassis Cover". 12. Plug all peripheral devices and the AC power cable into the server. 13. Power up the server.
Replacing the Front Panel Board
1. ...
P4000M family Service Guide - Page 98
... phone support on Intel® server boards, server chassis, server RAID controller cards, and Intel® Server Management.
NOTE
You must login in to the reseller site to obtain the 24x7 number.
Warranty Information
To obtain warranty information, visit the following Intel web site: http://www.intel.com/support/motherboards/server/sb/cs-010807.htm
Intel® Server Chassis P4000M Service Guide...
P4000M family Service Guide - Page 101
... part number (PBA number): RAID controller firmware version: Has the latest RAID firmware been tried? (Yes/No): RAID driver version: Has the latest RAID driver been tried? (Yes/No): RAID volumes configuration (disks & RAID level): RAID volume use (Boot device/Data Volume): Is BBU (Battery Backup Unit) installed? (Yes/No):
BBU part number:
88
Intel® Server Chassis P4000M Service Guide