Technical Product Specification - Page 53

... use the CPU/memory air duct to maintain system thermals.  To maintain system thermals, you must populate all hard drive bays with either a hard drive or drive blank.  You must remove AC power from the system prior to opening the chassis for service You can download the latest system documentation, drivers, and system software from the Intel® Support website...
Chassis Service Guide - Page 5

... product. For installation of supported spares and accessories For a list of supported Intel® spares and accessories Use this Document or Software Intel® Server Chassis H2000 Family Technical Product Specification See the section on the web page titled, "Architecture/Specifications". Intel® Server Chassis H2000, H2000WP, and H2000LP Family Quick Installation User's Guide See the...
Chassis Service Guide - Page 6

... Software See the section on the web page titled, "Software/Code". Intel® Deployment Assistant DVD Firmware and Drivers See the section on the web page titled, "Software/Code". Intel® Server Products - Product Safety and Regulatory Compliance Document See the section on the web page titled, "Regulations/Certification/Compliance". vi Intel® Server Chassis H2000 Family Service Guide
Chassis Service Guide - Page 43

... information on all Intel® Enterprise Server and Storage Platforms. Information available at the support site includes: - Latest BIOS, firmware, drivers and utilities - Product documentation, installation and quick start guides - Full product specifications, technical advisories and errata - Compatibility documentation for memory, hardware add-in cards, chassis support matrix and operating...
Chassis Service Guide - Page 46

... number (PBA number): RAID controller firmware version: Has the latest RAID firmware been tried? (Yes/No): RAID driver version: Has the latest RAID driver been tried? (Yes/No): RAID volumes configuration (disks and RAID level): RAID volume use (Boot device/Data Volume): Is BBU (Battery Backup Unit) installed? (Yes/No): BBU part number: Intel® Server System H2000JF Family Service Guide 35
Technical Product Specification - Page 40

...* MegaRAID SW RAID technology supporting SATA RAID levels 0,1,10, 5.  Intel® Rapid Storage Technology (RSTe) supporting SATA RAID levels 0,1,5,10. The server board is capable of supporting additional chipset embedded SAS and RAID options from the SCU controller when configured with one of several available Intel® RAID C600 Storage Upgrade Keys. Upgrade keys install onto a 4-pin...
Technical Product Specification - Page 43

... host controller can instruct the PCH to generate any of SMI#, NMI, SERR#, or TCO interrupt.  Function Disable: The Intel® C600 PCH provides the ability to disable the following integrated functions: LAN, USB, LPC, Intel® HD Audio, SATA, PCI Express*, or SMBus*. Once disabled, these functions no longer decode I/O, memory, or PCI configuration space. Also, no interrupts or power...
Technical Product Specification - Page 52

... server board is integrated and any additional system level components and options that may be installed. 4.1.1        IPMI 2.0 Features Baseboard management controller (BMC). IPMI Watchdog timer. Messaging support, including command bridging and user/session support Chassis device functionality, including power/reset control and BIOS...
Technical Product Specification - Page 65

... The Intel® Server Board S2600JF product includes support for an upgrade module to support the advanced server management functionality. Table 21. Basic and Advanced Management Features Feature IPMI 2.0 Feature Support In-circuit BMC Firmware Update FRB 2 Chassis Intrusion Detection Fan Redundancy Monitoring Hot-Swap Fan Support Acoustic Management Diagnostic Beep Code Support Power State...
Technical Product Specification - Page 68

... is intended to allow system administrators or users to mount a remote USB HDD or USB CD-ROM, floppy drive, or a USB flash disk as a remote device to the server. Once mounted, the remote device appears just like a local device to the server, allowing system administrators or users to install software (including operating systems), copy files, update BIOS, and so on, or boot the server from this...
Technical Product Specification - Page 188

... password 1 1 1 0 1 0 0 1 Entering BIOS setup 1 1 1 0 1 1 0 0 Flash Update 1 1 1 0 1 1 0 1 Legacy Option ROM initialization 1 1 1 0 1 0 0 0 DXE Drivers initialized 1 1 1 0 1 0 0 1 Transfer control to Boot Device Selection (BDS) 1 1 1 0 1 1 0 0 Calling Int 19. One beep unless silent boot is enabled. 1 1 1 0 1 1 0 1 Unrecoverable boot failure Pre-EFI Initialization Module (PEIM)/Recovery...
Technical Product Specification - Page 101

...live networking environment. This includes system BIOS, FRUSDR, BMC firmware, and hot-swap controller firmware. The system software can be updated using the Intel® Deployment CDROM that came with your system or can be downloaded from the Intel® website referenced at the bottom of this page.  System fans are not hot-swappable.  Only supported memory validated by Intel®...
Technical Product Specification - Page 105

...O X X O O X Started connecting drivers DXE Drivers 0xE7h O O O X O O X O Waiting for user input 0xE8h O O O X O X X X Checking password 0xE9h O O O X O X X O Entering BIOS setup 0xEAh O O O X O O X X Flash Update 0xEEh 0xEFh O O O X O O X X Calling Int 19. One beep unless silent boot is enabled. O O O X O O X O Unrecoverable boot failure Pre-EFI Initialization Module (PEIM)/Recovery 0x30h...
System Service Guide - Page 5

... for installing or replacing components such as the fan, power supply, and front panel board, among other components. Chapter 3 provides instructions on using the utilities that are shipped with the board or that may be required to update the system. This includes information for navigating through the BIOS Setup screens, performing a BIOS update, and resetting the password or BIOS defaults...
System Service Guide - Page 6

... technical information about this product. For installation of supported spares and accessories For a list of supported Intel® spares and accessories For server configuration guidance and compatibility For system power budget guidance For software to manage your Intel® Server System. For system firmware updates and onboard device drivers Product Safety and Regulatory document Use this...
System Service Guide - Page 48

... Upgrade Key Installing the Intel® Storage Upgrade Key The server board supports various Intel® Storage Upgrade Keys for different storage configuration. Below is the list of supported Storage Upgrade Key. Table 5. POST Progress Code LED Example Intel® RAID C600 Upgrade Key Options (Intel Product Codes) Key Color Description Default - No option key installed N/A 4 Port SATA...
System Service Guide - Page 71

Hardware Installations and Upgrades 3. Install the inner members to the chassis. Figure 89. Installing the Inner Member to the Chassis 4. Install the chassis to the fixed slides. Figure 90. Installing the Chassis to Rack Removing the Chassis from Rack Follow the below steps to remove the chassis from the rack. 1. Extend the slides. 58 Intel® Server System H2000JF Family Service Guide
System Service Guide - Page 85

... drivers 0xE6h 0xE7h 1 1 1 0 0 1 1 0 Started connecting drivers DXE Drivers 1 1 1 0 1 1 0 1 Waiting for user input 0xE8h 1 1 1 0 1 0 0 0 Checking password 0xE9h 1 1 1 0 1 0 0 1 Entering BIOS setup 0xEAh 1 1 1 0 1 1 0 0 Flash Update 0xEBh 1 1 1 0 1 1 0 1 Legacy Option ROM initialization 0xECh 1 1 1 0 1 0 0 0 DXE Drivers initialized 0xEDh 1 1 1 0 1 0 0 1 Transfer control to Boot Device...
System Service Guide - Page 86

... information on all Intel® Enterprise Server and Storage Platforms. Information available at the support site includes: - Latest BIOS, firmware, drivers and utilities - Product documentation, installation and quick start guides - Full product specifications, technical advisories and errata - Compatibility documentation for memory, hardware add-in cards, chassis support matrix and operating...
System Service Guide - Page 89

...RAID controller part number (PBA number): RAID controller firmware version: Has the latest RAID firmware been tried? (Yes/No): RAID driver version: Has the latest RAID driver been tried? (Yes/No): RAID volumes configuration (disks and RAID level): RAID volume use (Boot device/Data Volume): Is BBU (Battery Backup Unit) installed? (Yes/No): 76 Intel® Server System H2000JF Family Service Guide
Get Help Online

Get immediate support for your Intel H2000 questions from HelpOwl.com.

Recent Intel H2000-related questions:

Intel Manuals

Find free Intel H2000 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Corporate Office

Locate the Intel corporate office headquarters phone number, address and more at CorporateOfficeOwl.com.

Contact Information

Complete Intel customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Intel customer service rankings, employee comments and much more from our sister site.