Intel R2000WT driver and firmware
Related Intel R2000WT Manual Pages
Download the free PDF manual for Intel R2000WT and other Intel manuals at ManualOwl.com
User Guide - Page 21
... a remote IDE or USB CD-ROM, floppy drive, or a USB flash disk as a remote device to the server. After mounted, the remote device appears just like a local device to the server, allowing system administrators or users to install software (including operating systems), copy files, update BIOS, and so on, or boot the server from this device.
• KVM - Automatically senses video resolution for...
Technical Product Specification - Page 23
... v3 product family
2.3.1 System BIOS The system BIOS is implemented as firmware that resides in flash memory on the server board. The BIOS provides hardware-specific initialization algorithms and standard compatible basic input/output services, and standard Intel® Server Board features. The flash memory also contains firmware for certain embedded devices.
This BIOS implementation is based on...
Technical Product Specification - Page 27
Intel® Server Board S2600WT TPS
Instructions provided with the system update package downloaded from the Intel web site. Once the update has completed, the recovery jumper is switched back to its default position and the system is power cycled.
If the BIOS detects a partial BIOS update or the BMC asserts Recovery Mode GPIO, the BIOS will boot up with Recovery Mode. The difference is that...
Technical Product Specification - Page 57
... no loss of PCI resources (request/grant pair) or add-in card slot. Intel® RSTe functionality requires the following:
The SW-RAID option must be enable in BIOS Setup Intel® RSTe option must be selected in BIOS Setup Intel® RSTe drivers must be loaded for the installed operating system At least two SATA drives needed to support RAID levels 0 or...
Technical Product Specification - Page 101
... to mount a remote IDE or USB CDROM, floppy drive, or a USB flash disk as a remote device to the server. Once mounted, the remote device appears just like a local device to the server allowing system administrators or users to install software (including operating systems), copy files, update BIOS, or boot the server from this device. • KVM - Automatically senses video resolution for best...
Technical Product Specification - Page 118
... 1 - 2 (default) 9. Re-install the system top cover and reattach the AC power cords. 10. Power up the server 11. Strongly recommended: Boot into BIOS Setup immediately, go to the Security tab and set the
Administrator and User passwords if you intend to use BIOS password protection
11.4 Management Engine (ME) Firmware Force Update Jumper Block
When the ME Firmware Force Update jumper is...
Technical Product Specification - Page 119
... should only be used if the BMC firmware has gotten corrupted and requires re-installation. The following procedure should be followed:
Note: System Update files are included in the System Update Packages (SUP) posted to Intel's Download center web site. http://downloadcenter.intel.com
1. Turn off the system. 2. Remove the AC power cords
Note: If the BMC FRC...
Technical Product Specification - Page 44
... Data Records (SDRs) for any given system configuration must be loaded by the system integrator as part of the initial system integration process. SDRs are loaded using the FRUSDR utility which is part of the System Update Package (SUP) or One-boot Firmware Update (OFU) package which can be downloaded from the following Intel website:
http://downloadcenter.intel.com...
Technical Product Specification - Page 73
... no loss of PCI resources (request/grant pair) or add-in card slot. Intel® RSTe functionality requires the following:
The SW-RAID option must be enable in BIOS Setup Intel® RSTe option must be selected in BIOS Setup Intel® RSTe drivers must be loaded for the installed operating system At least two SATA drives needed to support RAID levels 0 or...
Technical Product Specification - Page 88
... to mount a remote IDE or USB CDROM, floppy drive, or a USB flash disk as a remote device to the server. Once mounted, the remote device appears just like a local device to the server allowing system administrators or users to install software (including operating systems), copy files, update BIOS, or boot the server from this device.
KVM - Automatically senses video resolution for best...
Technical Product Specification - Page 92
.... However, to ensure the latest sensor data is installed, the SDR data should be updated to the latest available as part of a planned system software update.
Make sure the latest system software is loaded on the server. This includes System BIOS, BMC Firmware, ME Firmware and FRUSDR. The latest system software can be downloaded from http://downloadcenter.intel.com.
82
Revision 1.0
Technical Product Specification - Page 60
... sensor data is installed, the SDR data should be updated to the latest available as part of a planned system software update.
The FRUSDR utility for the given server platform can be downloaded as part of the System Update Package (SUP) or One-boot Firmware Update (OFU) package which from the following Intel web site:
http://downloadcenter.intel.com.
Note: The...
Technical Product Specification - Page 64
... Card - System Configuration Requirements
For best system performance and proper fan speed control, ensure the system is configured as follows:
• The following BIOS Setup Utility Options must be set:
MMIO over 4GB = Enabled MMIO Size = 256GB
Intel highly recommends that the latest available system software be installed. The latest system update package can be downloaded...
Technical Product Specification - Page 95
... no loss of PCI resources (request/grant pair) or add-in card slot. Intel® RSTe functionality requires the following:
The SW-RAID option must be enable in BIOS Setup Intel® RSTe option must be selected in BIOS Setup Intel® RSTe drivers must be loaded for the installed operating system At least two SATA drives needed to support RAID levels 0 or...
Technical Product Specification - Page 117
... to mount a remote IDE or USB CDROM, floppy drive, or a USB flash disk as a remote device to the server. Once mounted, the remote device appears just like a local device to the server allowing system administrators or users to install software (including operating systems), copy files, update BIOS, or boot the server from this device.
• KVM - Automatically senses video resolution for best...
Technical Product Specification - Page 121
.... However, to ensure the latest sensor data is installed, the SDR data should be updated to the latest available as part of a planned system software update.
Make sure the latest system software is loaded on the server. This includes System BIOS, BMC Firmware, ME Firmware and FRUSDR. The latest system software can be downloaded from http://downloadcenter.intel.com.
Revision 1.0
109
System Integration and Service Guide - Page 7
... Product Specification
http://support.intel.com/support/motherboards/server /sb/CS-034824.htm Intel® Server Board S2600WT Product Family Spares and Accessories List and Configuration Guide Intel® Server Configurator tool
http://serverconfigurator.intel.com
For system power budget guidance
For system firmware updates, onboard device drivers, and software to manage your Intel® Server...
System Integration and Service Guide - Page 9
... and Service 42
3.1
Slimline Optical Drive - Installation and Removal 43
3.1.1 Slimline Optical Drive Installation 43
3.1.2 Slimline Optical Drive Removal 45
3.2
Power Supply Module - Installation / Removal 46
3.2.1 Power Supply Module Installation 46
3.2.2 Power Supply Module Removal 46
3.3
Power Cord Retention Strap Installation 47
3.4
Intel® SAS RAID Module Installation...
System Integration and Service Guide - Page 10
... System R2000WT Product Family System Integration and Service Guide
3.12.2 3.5" Front Drive Bay Support ...60
3.12.3 Intel® RAID Expander Card Cabling Overview 61
3.13
R2208WTxxx to R2216WTxxx Upgrade 62
3.14
R2208WTxxx / R2216WTxxx to R2224xxx Upgrade 62
4. System Software Updates and Configuration 67
4.1
Updating the System Software Stack 67
4.2
Using the BIOS Setup Utility...
System Integration and Service Guide - Page 66
... behind the onboard NIC 2 port on the back edge of the server
board. 3. To install the key, place it over the connector and confirm the orientation of the key matches that of
the connector 4. Press the key down onto the connector.
3.6.2 Removing the SATA RAID 5 Upgrade Key
1. Power off the system and disconnect the power cable(s) 2. Remove the system...