XChip Direct - Product Brief - Page 1

...x86-class processor that includes a built in Ethernet MAC and 10-100 PHY, 256 KB zero wait-state SRAM, up to 2 GPIOs and a high-performance serial UART in a compact 12mm x 12mm 184 BGA RoHS-compliant, industrial temperature package. Simply connect the serial port to the XChip Direct and load the Lantronix supplied royalty free standard application and network protocol firmware in an external Flash...
XChip Direct - Product Brief - Page 2

... Firmware (Licensed with XChip Direct) Network Protocols: TCP/IP, UDP/IP, ARP, ICMP, SNMP,TFTP,Telnet, DHCP, BOOTP and AutoIP Serial to Ethernet (LAN) Tunneling Application Software Utilities (Licensed with XChip Direct) DeviceInstaller software COM Port Redirector Note: OEM supplies Flash Memory, RJ45-Magnetics, Clock crystal and regulated power inputs. Reference Design XChip Direct Ordering...
XChip Direct - User Guide - Page 2

.... Contacts Lantronix Corporate Headquarters 15353 Barranca Parkway Irvine, CA 92618, USA Phone: 949-453-3990 Fax: 949-453-3995 Technical Support Online: www.lantronix.com/support Sales Offices For a current list of our domestic and international sales offices, go to the Lantronix web site at www.lantronix.com/about/contact DeviceLinx™ XPort Direct/XChip Direct SoC User Guide 2
XChip Direct - User Guide - Page 3

...be required to correct the interference. Changes or modifications to this device not explicitly approved by Lantronix will void the user's authority to operate this device. Date Rev. Firmware Comments 1/07 A Initial release 5/07 B 6.1 Added information about product support for RS485. 8/07 C 6.5 Added XChip Direct information. DeviceLinx™ XPort Direct/XChip Direct SoC User Guide 3
XChip Direct - User Guide - Page 4

.... ("Lantronix") for the computer software (including firmware) accompanying this FLA, which may include associated media, printed materials, and "online" or electronic documentation (collectively the "Software"). An amendment or addendum to this FLA may accompany the Software. RECIPIENT AGREES TO BE BOUND BY THE TERMS OF THIS FLA BY OPENING THIS SEALED MEDIA PACKAGE, INSTALLING, DOWN LOADING, OR...
XChip Direct - User Guide - Page 5

... contemporaneous oral or written communications, proposals and representations with respect to the Software or any other subject matter covered by this FLA. To the extent the terms of any Lantronix policies or programs for support services conflict with the terms of this FLA, the terms of this FLA shall control. DeviceLinx™ XPort Direct/XChip Direct SoC User Guide 5
XChip Direct - User Guide - Page 6

...and Trademark 2 Contacts 2 Disclaimer and Revisions 3 XChip Direct Firmware License Agreement 4 1: Using This Guide 10 Purpose and Audience 10 Chapter Summary 10 Utilities 11 Additional Documentation 11 2: Introduction 12 Capabilities 12 Applications 12 Protocol Support 13 Addresses and Port Numbers 13 Hardware Address 13 IP Address 13 Port Numbers 13 Assigning an IP...
XChip Direct - User Guide - Page 8

... Port and DeviceInstaller 50 10: Monitor Mode 52 Entering Monitor Mode Using the Serial Port 52 Entering Monitor Mode Using the Network Port 52 Monitor Mode Commands 52 11: Troubleshooting 55 Problems and Error Messages 55 Technical Support 57 A: Alternative Ways to Assign an IP Address 58 DHCP 58 AutoIP 58 BOOTP 59 DeviceLinx™ XPort Direct/XChip Direct SoC User Guide...
XChip Direct - User Guide - Page 10

... Settings 8: GPIO Interface 9: Firmware Upgrades 10: Monitor Mode Description Describes the main features of the XPort Direct and the protocols it supports. Provides information for getting your unit up and running, using DeviceInstaller to assign an IP address. Provides instructions for accessing Setup Mode (command line interface) using a Telnet connection through the network or the serial port...
XChip Direct - User Guide - Page 11

... and related documentation are available for download on the Lantronix web site www.lantronix.com: Utility Com Port Redirector Description A Windows-based utility to create a virtual com port. The Com Port Redirector User Guide explains how to use it. DeviceInstaller A utility to configure IP addresses and locate Lantronix devices on the local network. DeviceInstaller's online Help provides...
XChip Direct - User Guide - Page 13

... IP address and a port number. For example, a Telnet application commonly uses port number 23. A port number is similar to an extension on a phone system. The unit's serial channel (port) can be associated with a specific TCP/UDP port number. Port number 9999 is reserved for access to the unit's Setup (configuration) Mode window. DeviceLinx™ XPort Direct/XChip Direct SoC User Guide 13
XChip Direct - User Guide - Page 15

... for assigning an IP to your unit. We recommend that you manually assign the IP address over the network using DeviceInstaller software, which is on the product CD. Note: To use a serial connection instead of an Ethernet connection to configure the device, see 4: Configuration via Telnet or Serial Port (Setup Mode) on page 20. DeviceLinx™ XPort Direct/XChip Direct SoC User Guide 15
XChip Direct - User Guide - Page 16

... The unit's IP address is normally set to 0.0.0.0 at the factory. The hardware address is on the product label. The unit is DHCP-enabled as the default. To assign an IP address manually: 1. Click StartÆPrograms Æ LantronixÆDeviceInstallerÆDeviceInstaller. If your PC has more than one network adapter, a message displays. Select an adapter and click OK...
XChip Direct - User Guide - Page 17

... Direct's firmware is upgradeable as newer version become available. Non-configurable field. Displays the XPort Direct's current IP address. Non-configurable field. Displays the number of COB partitions supported. Non-configurable field. Indicates whether the current IP address on the XPort Direct was set manually or assigned by DHCP. DeviceLinx™ XPort Direct/XChip Direct SoC User Guide...
XChip Direct - User Guide - Page 41

... of the unit. Disable Telnet Setup (N) ? _ Disable TFTP Firmware Upgrade This setting defaults to the N (No) option. The Y (Yes) option disables the use of TFTP to perform network firmware upgrades. With this option, you can download firmware upgrades over the serial port using DeviceInstaller's Recover Firmware procedure. Disable TFTP Firmware Update (N) : _ Disable Port 77FE (Hex) Note: If you...
XChip Direct - User Guide - Page 43

... - 1400) Alternate MAC Ethernet Connection Type No 0 (resulting in an operational value of 1400) Disabled ( for OEM use only) 0 (auto-negotiate) Security Settings Defaults Disable Telnet setup No Disable TFTP Firmware Update No Disable Port 77FEh No Disable ECHO ports Yes Enable Enhanced password No Disable Port 77F0h No DeviceLinx™ XPort Direct/XChip Direct SoC User Guide 43
XChip Direct - User Guide - Page 49

... TFTP: Graphical User Interface To download new firmware from a computer: 1. Use a TFTP client to send a binary file to the unit (*.ROM to upgrade the unit's internal operational code. Note: TFTP requires the .ROM (binary) version of the unit's internal operational code. 2. In the TFTP server field, enter the IP address of the unit being upgraded. 3. Select Upload operation and...
XChip Direct - User Guide - Page 50

...message displays. Select an adapter and click OK. 2. From the Tools menu, select Advanced/Recover Firmware. The Serial Port Firmware Upgrade window displays. 3. For Port on PC, enter the COM port on the PC that is connected to the serial port of the Lantronix unit. 4. For Device Model, be sure the appropriate XPort Direct device displays. DeviceLinx™ XPort Direct/XChip Direct SoC User Guide...
XChip Direct - User Guide - Page 51

... the file transfer completes, the message "Successful, Click OK to Close" appears. 8. Click the OK button to complete this procedure. Note For more information, see Recovering Firmware in the DeviceInstaller online Help. DeviceLinx™ XPort Direct/XChip Direct SoC User Guide 51
XChip Direct - User Guide - Page 57

...@lantronix.com Firmware downloads, FAQs, and the most up-to-date documentation are available at: www.lantronix.com/support When you report a problem, please provide the following information: ‹ Your name, and your company name, address, and phone number  ‹ Lantronix model number ‹ Lantronix MAC number ‹ Software version (on the first screen shown when you Telnet to port...
Get Help Online

Get immediate support for your Lantronix XChip Direct questions from HelpOwl.com.

Recent Lantronix XChip Direct-related questions:

Lantronix Manuals

Find free Lantronix XChip Direct manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Corporate Office

Locate the Lantronix corporate office headquarters phone number, address and more at CorporateOfficeOwl.com.

Contact Information

Complete Lantronix customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Lantronix customer service rankings, employee comments and much more from our sister site.