Lantronix EDS-MD driver and firmware
Related Lantronix EDS-MD Manual Pages
Download the free PDF manual for Lantronix EDS-MD and other Lantronix manuals at ManualOwl.com
EDS-MD - Product Brief - Page 1
... to and from remote device servers over the Internet with the highest level of security.
EDS-MD Highlights:
> UL and IEC-60601 compliance provides port isolation to protect connected medical devices
> Securely connect any medical device with a serial interface to the network using enterprise-level SSL and SSH
> Gigabit Ethernet offers increased bandwidth for higher performance
Set up and...
EDS-MD - Product Brief - Page 2
...-01
> Description
EDS-MD 4-PORT DEVICE SERVER, ROHS EDS-MD 8-PORT DEVICE SERVER, ROHS EDS-MD 16-PORT DEVICE SERVER, ROHS
• ESD Protection - 15kV • Circuit and port isolation - 1.5KVAC
> Power Cords*
2 •
USB Host ports Output Capability • Circuit and port
iU=soS0lBa.5t-AiAonre-ce1p.5tKaVclAeCconnectors 993300--007734--RR
1 Ethernet port - RJ45 connector^
930...
EDS-MD - Product Brief (A4 Format) - Page 1
... to and from remote device servers over the Internet with the highest level of security.
EDS-MD Highlights:
> UL and IEC-60601 compliance provides port isolation to protect connected medical devices
> Securely connect any medical device with a serial interface to the network using enterprise-level SSL and SSH
> Gigabit Ethernet offers increased bandwidth for higher performance
Set up and...
EDS-MD - Product Brief (A4 Format) - Page 2
...
• 600MHz ARM 11 processor
Call: +852 3428.2338
Call: +81.3.6277.8802
• 8 MB Flash • 4 GB SD Card (internal only)
Email: asiapacific_sales@lantronix.com
Email: japan_sales@lantronix.com
• 256 MB SDRAM • Real Time Clock with Battery back-up • Onboard Thermal Sensor
> Part Number
EDSOR04P-01-R
> Description
EDS-MD 4-PORT DEVICE SERVER, ROHS
> Physical...
EDS-MD - User Guide - Page 2
... assumes no responsibility for any errors that may appear in this guide.
Revision History
Date September 2011 October 2011 November 2011 November 2011
Rev. A B C D
Comments Initial Document for firmware release 7.2.0.0. Updated power cord part number information. Updated ethernet port information and cover product image. Added Suppliers Declaration of Conformity document.
EDS-MD User Guide
2
EDS-MD - User Guide - Page 4
... Hardware Components 23
Serial Ports 24 Ethernet Port 24 LEDs 24 Reset to Default Button 25
To restore factory default settings 25 Technical Specification 26 Installing the EDS-MD 27
Finding a Suitable Location 27 Connect the EDS-MD to one or more serial devices 27
4: Using DeviceInstaller
28
Accessing EDS-MD Using DeviceInstaller 28 Device Detail Summary 28
5: Configuration...
EDS-MD - User Guide - Page 10
... Manager 80 Using the CLI 80 Using XML 80
13: Updating Firmware
81
Obtaining Firmware 81 Loading New Firmware 81
14: VIP Settings
82
Virtual IP (VIP) Configuration 82 To Configure VIP Settings 82 Using Web Manager 82 Using the CLI 82 Using XML 82
Virtual IP (VIP) Status 82 To View VIP Status 82
EDS-MD User Guide
10
EDS-MD - User Guide - Page 15
...Settings 13: Updating Firmware
14: VIP Settings
15: Branding the EDS-MD4/8/16 Appendix A: Technical Support Appendix B: Binary to Hexadecimal Conversions Appendix C: Compliance Appendix D: Lantronix Cables, Adapters and Serial Port Pinouts
Description Main features of the product and the protocols it supports. Includes technical specifications. Instructions for installing the EDS-MD.
Instructions...
EDS-MD - User Guide - Page 20
... easily with Ethernet networking and web server capabilities. EDS-MD models are available in 4, 8 and 16 port configurations.
Key Features
Power Supply: Direct plug-in to wall ac with universal 100-240 VAC input Controller: 32-bit ARM11 microprocessor running at 600 megahertz (Mhz) Memory: 64 megabit Flash, 2 gigabit DDR2 DRAM, and a 4 gigabyte SDHC card (internal
only...
EDS-MD - User Guide - Page 24
...
USB Port
RJ45 Ethernet Ports
Note: Ethernet ports 2 and 3 will become operational with a future firmware update.
Power Connector
Serial Ports
In the front of the device, the EDS-MD4 has 4 serial ports, the EDS-MD8 has 8 serial ports, and the EDS-MD16 has 16 serial ports. All are configured as DTE and support up to 921600 baud.
Ethernet Port
The back panel of the EDS-MD4/8/16 provides a network...
EDS-MD - User Guide - Page 25
... the side of the housing, accessible with a paper clip or other similar object, through a pin hole.
To restore factory default settings:
1. Power cycle the unit. 2. During the bootup, hold down the reset-to-default button for a minimum of 25 seconds. 3. Release the button. The firmware restores factory default settings to the configuration.
EDS-MD User Guide
25
EDS-MD - User Guide - Page 26
...Installation of EDS-MD4/8/16 Device Servers
Technical Specification
Category
NETWORK INTERFACE Ethernet Ports
Left LED Indicator Right LED Indicator Isolation from internal circuit Isolation from adjacent port
USB INTERFACE USB Ports Output Capability Isolation from internal circuit Isolation from adjacent port
SERIAL INTERFACE Serial Ports
Baud rate Serial Line Formats
Modem Control Flow Control...
EDS-MD - User Guide - Page 28
... or DHCP server is found. These addresses are not routable.
Accessing EDS-MD Using DeviceInstaller
Note: Make note of the MAC address. It is needed to locate the EDS-MD4/8/16 using DeviceInstaller.
To use the DeviceInstaller utility, first install the latest version from the downloads page on the Lantronix web site www.lantronix.com/downloads.
1. Run the executable to start the...
EDS-MD - User Guide - Page 29
... Settings (continued)
Group
Comments
Device Family Type ID Hardware Address Firmware Version Extended Firmware Version Online Status
IP Address
IP Address was Obtained
Subnet Mask Gateway Number of Ports Supports Configurable Pins Supports Email Triggers Telnet Enabled Telnet Port Web Enabled Web Port Firmware Upgradable
Description
Configurable field. Enter a group to categorize the EDS-MD...
EDS-MD - User Guide - Page 35
... of milliseconds to pass from the last character received before the driver forwards the received serial bytes. By default, the delay is four character periods at the current baud rate (minimum 1 msec).
Set the number of threshold bytes which need to be received in order for the driver to forward received characters.
EDS-MD User Guide
35
EDS-MD - User Guide - Page 53
... default port is 514.
Syslog Settings State
Host Remote Port
Table 9-3 Syslog Settings
Description
Select to enable or disable the syslog: Enabled Disabled (default) Enter the IP address of the remote server to which system logs are sent for storage. Enter the number of the port on the remote server that supports logging services. The default is 514.
EDS-MD User Guide
53
EDS-MD - User Guide - Page 74
... 11-12 System Settings
Description
Reboots the device.
Restores the device to the original factory settings. All configuration will be lost. The EDS-MD automatically reboots upon setting back to the defaults.
FTP to the EDS-MD. Write the new firmware file to firmware.rom on the EDS-MD. The device automatically reboots upon the installation of new firmware. See the section, FTP Settings on page 53...
EDS-MD - User Guide - Page 81
...): admin 331 Please specify the password. Password: 230 Login successful. Remote system type is UNIX. Using binary mode to transfer files. ftp> put edsmd_7_2_0_0R8.rom firmware.rom 200 PORT command successful. Consider using PASV. 150 Ok to send data. 226 File receive OK. 9308164 bytes sent in 3.05 seconds (3047859 bytes/s) ftp> quit 221 Goodbye.
EDS-MD User Guide
81
EDS-MD - User Guide - Page 86
...com or eu_support@lantronix.com Firmware downloads, FAQs, and the most up-to-date documentation are available at http://www.lantronix.com/support When you report a problem, please provide the following information: Your name, and your company name, address, and phone number Lantronix model number Lantronix serial number/MAC address Firmware version (on the first...
EDS-MD - Quick Start Guide - Page 1
EDS-MD Quick Start Guide
What's in the BoX
RJ45 Loopback Adapter
EDS-MD
RJ45 CAT5E Ethernet Cable
Power Cord
1 Install DeviceInstaller™
1. Download the latest version of DeviceInstaller from http://www.lantronix.com/downloads
2. Run the executable to start the installation process on the computer being used to configure EDS-MD.
3. Respond to the installation wizard prompts. 4. When ...