Intel R2000GL driver and firmware

Drivers and firmware downloads for this Intel item

We have a direct link to download Intel R2000GL drivers, firmware and other resources directly from the Intel site. To protect our site from spammers you will need to verify you are not a robot below in order to access the download link.

R2000GL driver download page on the Intel site

Related Intel R2000GL Manual Pages

Download the free PDF manual for Intel R2000GL and other Intel manuals at ManualOwl.com

Service Guide - Page 5

... information about this product. For a quick guide of how to assemble the server system and install components For product list and supported Intel spares and accessories For server configuration guidance and compatibility For system power budget guidance For system firmware updates and onboard device drivers and software to manage your Intel® Server System. Product Safety and Regulatory...
Service Guide - Page 29

...activate the port SCU1 (4-7) on the server board, a proper Intel® RAID C600 Upgrade Key must be installed. For instructions, see Intel® RAID C600 Upgrade Key Installation Guide. Note: A second SSD is supported when the optical drive is NOT in use. For cable routing, please refer to Figure 23. Figure 22. Cable Routing - 8 x 3.5" HDD Intel® Server System R2000GZ/GL Service Guide 17
Service Guide - Page 31

...activate the port SCU1 (4-7) on the server board, a proper Intel® RAID C600 Upgrade Key must be installed. For instructions, see Intel® RAID C600 Upgrade Key Installation Guide. Note: A second SSD is supported when the optical drive is NOT in use. For cable routing, please refer to Figure 26. Figure 24. Cable Routing - 8 x 2.5" HDD Intel® Server System R2000GZ/GL Service Guide 19
Service Guide - Page 33

Hardware Installations and Upgrades For system with 24 x 2.5" hard drive bay: Note: To activate the port SCU1 (4-7) on the server board, a proper Intel® RAID C600 Upgrade Key must be installed. For instructions, see Intel® RAID C600 Upgrade Key Installation Guide. Figure 26. Cable Routing - 24 x 2.5" HDD Intel® Server System R2000GZ/GL Service Guide 21
Service Guide - Page 53

... 4-pin key header next to Riser Slot 1. Carefully pickup the Intel® RAID C600 Upgrade Key. Match the Key and connector orientation and press down to install. Figure 66. Installing the Intel® RAID C600 Upgrade Key Removing the Intel® RAID C600 Upgrade Key Pull up the key to remove it from the mother board. Intel® Server System R2000GZ/GL Service Guide 41
S2600GZ/GL - Page 50

... MB to 32 GB. • Support USB Mass Storage Class requirements for Boot capability. 3.3.3 Embedded Serial ATA (SATA)/Serial Attached SCSI (SAS)/RAID Support The Intel® C602 chipset provides storage support from two integrated controllers: AHCI and SCU. By default the server board will support up to 6 SATA ports: Two single 6Gb/sec SATA ports routed from the AHCI controller to the two white...
S2600GZ/GL - Page 51

... Software Stack  Software RAID with system providing memory and CPU utilization  Supported RAID Levels - 0,1,5,10 o 4 & 8 Port SATA RAID 5 support provided with appropriate Intel® RAID C600 Upgrade Key o 4 & 8 Port SAS RAID 5 support provided with appropriate Intel® RAID C600 Upgrade Key  Maximum drive support = 8  Open Source Compliance = Binary Driver...
S2600GZ/GL - Page 52

... a driver) Note: No boot drive support to targets attached through SAS expander card. 1) See latest product errata list for support status. Product Errata are documented in the Intel® Server Board S2600GZ/GL, Intel® Server System R1000GZ/GL, Intel® Server System R2000GZ/GL Monthly Specification Update which can be downloaded from www.intel.com. 3.3.4 Manageability The chipset...
S2600GZ/GL - Page 241

...; Intel® Server System R2000GZ/GL Technical Product Specification  Intel® Deployment Assistant (IDA) 5.2 Users Guide  One Boot Flash Update Installation and Users GuideIntel® Active System Control Console User GuideIntel® Intelligent Power Node Manager White Paper  Intel® System Management Software Installation Guide Revision...
R1000GZ and R1000GL - Page 48

...on the server board is an Intel® C602 chipset that provides embedded storage support via two integrated controllers: AHCI and SCU. The server board (with no additional storage options installed) will support up to six SATA ports: • Two 6 Gb/sec SATA ports routed from the AHCI controller to two white 7-pin SATA ports labeled "SATA-0" and "SATA-1" on the server board. Embedded RAID levels...
R1000GZ and R1000GL - Page 49

... providing memory and CPU utilization • Supported RAID Levels - 0,1,5,10 o 4 & 8 Port SATA RAID 5 support provided with appropriate Intel® RAID C600 Upgrade Key o 4 & 8 Port SAS RAID 5 support provided with appropriate Intel® RAID C600 Upgrade Key • Maximum drive support = 8 o NOTE: ESRT2 has no SAS Expander Support • Open Source Compliance = Binary Driver (includes...
R1000GZ and R1000GL - Page 61

... H3 are only supported when CPU-2 is installed. • The CPU-2 heat sink must be installed at all times, with or without a processor installed. • PCI Riser Slot-2 is only functional when two processors are installed. • The Mini-SAS connector labeled "SCU_01(4-7)" on the server board is only functional when an appropriate Intel® RAID C600 Upgrade Key is installed. • Many...
R2000GZ and R2000GL - Page 46

....06.0002 or later  BMC Firmware 01.17.4207 or later  FRUSDR 1.09 or later Intel highly recommends that the latest available system software be installed. The latest system update package can be downloaded from the following Intel web site: http://downloadcenter.intel.com • The following BIOS Setup Utility Options must be set:  MMIO over 4GB = Enabled...
R2000GZ and R2000GL - Page 57

... board is an Intel® C602 chipset that provides embedded storage support via two integrated controllers: AHCI and SCU. The standard server board (with no additional storage options installed) will support up to six SATA ports: • Two single 6 Gb/sec SATA ports routed from the AHCI controller to two white 7-pin SATA ports labeled "SATA-0" and "SATA-1" on the server board. Embedded RAID...
R2000GZ and R2000GL - Page 58

... providing memory and CPU utilization • Supported RAID Levels - 0,1,5,10 o 4 & 8 Port SATA RAID 5 support provided with appropriate Intel® RAID C600 Upgrade Key o 4 & 8 Port SAS RAID 5 support provided with appropriate Intel® RAID C600 Upgrade Key • Maximum drive support = 8 o NOTE: ESRT2 has no SAS Expander Support • Open Source Compliance = Binary Driver (includes...
R2000GZ and R2000GL - Page 77

... or without a processor installed • DIMM slots E1 thru H3 are only supported when CPU-2 is installed. • PCI Riser Slot-2 is only functional when two CPUs are installed. • The Mini-SAS connector labeled "SCU_1(4-7)" on the server board is only functional when an appropriate Intel® RAID C600 Upgrade Key is installed. • Many integrated on-board SAS and RAID options are...
Monthly Specification Update - Page 3

...Upgrade Key replacement Issue 9 17. Intel® LAN driver installation failure on Windows* 7 9 18. On-board VGA cannot be set to the highest resolution (1920x1080 and higher).. 10 19. Hard drive locate LED may not instantly respond to the locate command if backplane is connected through SAS expander to a RAID controller 10 20. Integrated BMC Web Console - Sensor Readings Page - Memory...
Monthly Specification Update - Page 7

... under ESRT2 mode of the SCU controller 15. Fix Hard drives connected through SAS expander can't be detected in legacy mode 16. Fixed Intel® RAID C600 Upgrade Key replacement Issue 17. Fixed Intel® LAN driver installation failure on Windows* 7 18. Fixed On-board VGA cannot be set to the highest resolution (1920x1080 and higher) 19. Fixed Hard drive locate LED may not instantly...
Monthly Specification Update - Page 11

... Intel ® C600 RAID upgrade key (any of RKSAS4, RKSAS4R5, RKSAS8, RKSAS8R5) is installed to enable SAS support capablity under ESRT2 mode while SAS drivers are used, the system may halt at the boot stage. Implication User may see a system halt with no RAID keys installed with SAS drivers used and ESRT2 enabled. User should use SATA drives only if no RAID...
Monthly Specification Update - Page 14

... be fixed in a future BIOS release. None. 16. Intel® RAID C600 Upgrade Key replacement Issue Problem Implication Status Workaround With Manageability Engine (ME) Firmware 02.01.05.069, the server may detect the incorrect Storage Control Unit (SCU) Redundant Array of Inexpensive/Independent Disks (RAID) information after installing or replacing the RAID upgrade key. The board or system may...
Get Help Online

Get immediate support for your Intel R2000GL questions from HelpOwl.com.

Recent Intel R2000GL-related questions:

Intel Manuals

Find free Intel R2000GL manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Corporate Office

Locate the Intel corporate office headquarters phone number, address and more at CorporateOfficeOwl.com.

Contact Information

Complete Intel customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Intel customer service rankings, employee comments and much more from our sister site.