Lantronix EMG 8500 - Edge Management Gateway driver and firmware
Drivers and firmware downloads for this Lantronix item
Related Lantronix EMG 8500 - Edge Management Gateway Manual Pages
Download the free PDF manual for Lantronix EMG 8500 - Edge Management Gateway and other Lantronix manuals at ManualOwl.com
EMG Quick Start Guide - Page 1
...Edge Management Gateway
!
Thank you for choosing Lantronix. Please register the EMG 8500 in order to receive notifications for firmware and documentation updates at www.lantronix.com/product-registration.
WHAT'S IN THE BOX
Quick Start Guide START
EMG 8500
EMG851210SP with USB and RJ45 FRUs shown. Additional FRU combinations are available.
Accessories
External Universal AC (100W, 12V) Power...
EMG Quick Start Guide - Page 2
... Guide
Edge Management Gateway
4. IP ADDRESSING
The EMG 8500 network ports (Ethernet 1 and Ethernet 2) default to DHCP-assigned IP addresses. If you want to assign a different IP address, it must be within a valid range, unique to your network, and on the same subnet as your workstation.
Note: You can view the IP address by running the Lantronix Provisioning Manager (LPM) application. Download...
AUS Supplier s Declaration of Conformity: Lantronix EMG8500 - Page 1
... Address (Australian)
Unit 308, 469-481 High St Northcote, VIC 3070
OR ACN/ARBN
84156023504
Product details
Product description - brand name, type, current model, lot, batch or serial number (if available), software/firmware version (if applicable)
Edge Management Gateway,
Model EMG8500 (including LTE/4G and Wi-Fi Connectivity Modules).
Compliance - applicable standards and other supporting...
EMG User Guide - Page 4
... network path
support, with fail-over and fail-back.
Note: EMG 8500 firmware cannot be installed on EMG 7500, and vice versa.
July 2020
D Updated for firmware release 8.4.0.0R9. It contains the following software changes for EMG 8500 and EMG 7500:
For the cellular modem that acquires the IP address dynamically, if the IP address is configured as the default gateway, fail-over gateway...
EMG User Guide - Page 22
....
Document EMG 8500 Quick Start Guide or EMG 7500 Quick Start Guide
EMG 8500 Product Brief or EMG 7500 Product Brief
Description
Provides accessories and part number information, hardware installation instructions, directions to connect the EMG unit, and network IP configuration information.
Provides product overview and specifications.
EMG™ Edge Management Gateway User Guide
22
EMG User Guide - Page 25
... types of IT equipment: Servers: Unix, Linux, Windows, and others. Networking equipment: Routers, switches, storage networking. Telecom: PBX, voice switches. Other systems with serial interfaces: Heating/cooling systems, security/building access
systems, uninterruptible power supply (UPS), medical devices.
EMG™ Edge Management Gateway User Guide
25
EMG User Guide - Page 26
...
Protocol Support
The EMG supports the following protocols: TCP/IP network protocol SSH, TLS, SSL, Telnet and TCP for connections in and out of device ports DHCP and BOOTP for dynamic IP address assignment DNS for IP address name resolution SNMP for remote monitoring and management SCP, FTP, and SFTP for file transfers and firmware upgrades...
EMG User Guide - Page 64
... Quick Setup page:
1. Open a web browser (Firefox, Chrome or Internet Explorer web browsers with the latest browser updates).
2. In the URL field, type https:// followed by the IP address of your EMG.
Note: The web server listens for requests on the unencrypted (HTTP) port (port 80) and redirects all requests to the encrypted (HTTPS) port (port 443).
EMG™ Edge Management Gateway User Guide...
EMG User Guide - Page 89
...the Eth2 Ethernet port only. For internal cellular modems (EMG models only), see Cellular Modem Settings.
Select an integrated external device to be used as the fail-over gateway. Currently the Lantronix PW XC HSPA+ Cellular Gateway and the Sierra Wireless ES450 Cellular Gateway are supported. When using an internal cellular modem as the failover gateway, the Fail-over Device should be set to None...
EMG User Guide - Page 91
... depend on the model of the EMG unit.
Load Cellular Gateway Firmware Options
USB Port
The USB Port selection becomes active when you choose to Load Firmware via USB. EMG provides one USB port called U1 in the interface. The firmware files must be stored in the top level directory of the USB flash drive.
FTP/SFTP/SCP Server
Enter the IP address or host name of the server...
EMG User Guide - Page 93
... Cellular Settings web page allows the user to configure parameters that determine how the EMG cellular modem network behaves, and to update the cellular modem firmware.
To complete the Cellular Settings page: 1. Click the Network tab and select the Cellular Modem option. The following page displays:
Figure 7-4 Network > Cellular Modem Settings Page
EMG™ Edge Management Gateway User Guide...
EMG User Guide - Page 95
... the APN set to m2m.com.attz and is using DHCP addressing Current Time: the number of seconds since the modem booted Temperature: the modem temperature in Celsius Reset Counter: the number of times the modem has been software reset Mode: indicates if the modem is online with the cellular network
EMG™ Edge Management Gateway User Guide
95
EMG User Guide - Page 99
...version that is the default firmware for the current EMG release. Updating the firmware or resetting the firmware requires a reboot in order for the change to take effect.
To update the WiFi firmware:
1. On the Network > Wireless Settings page, click the Update WiFi Firmware link. The Update WiFi Firmware page appears.
Figure 7-5 Update WiFi Firmware
EMG™ Edge Management Gateway User Guide...
EMG User Guide - Page 176
... management of multiple Lantronix ITM devices. A browser based interface (including mobile phone app support) allows an administrator to view status, send commands, view logs and charts and update firmware. Each Lantronix device can communicate with the cloud server or on-premise server, sending status updates and responding to commands sent by the server.
An EMG gateway requires a unique Device...
EMG User Guide - Page 177
... a response to the newline character within approximately one second, and this may result in the Device Port Connection Status being set to Disconnected.
8. CLI Commands
CLI commands can be issued to a set of EMG from ConsoleFlow. CLI commands which require user input for a confirmation or prompt, or require some other user interaction
EMG™ Edge Management Gateway User Guide
177
EMG User Guide - Page 179
... Eth1 MAC address appended.
Long description that is displayed in the ConsoleFlow server UI.
The unique device identifier. The ID is 32 alphanumeric characters. The ID may be provisioned using Lantronix Provisioning Manager (LPM). Contact Lantronix Tech Support for more information on LPM.
Displays the serial number.
Remote Access Idle Timeout
Remote Access CLI Timeout
Remote Access Device Port...
EMG User Guide - Page 237
..., which will interrupt the power provided by the RPM. Some PDUs and UPSes have a default delay that they will wait before initiating a shutdown; this setting may be visible in the raw data (see above) as "ups.delay.shutdown".
Deletes the selected RPM, after a confirmation.
Figure 11-2 RPM Shutdown Order
EMG™ Edge Management Gateway User Guide
237
EMG User Guide - Page 252
...enter device port configurations.
Right to enter modem settings for USB modems and to control USB storage devices. Right to view and enter settings for SD card.
5. To save, click the Apply button. If the type of script is Interface or Custom, the script will be validated before it is saved. Once the script is saved, the main Devices > Scripts page is displayed.
EMG™ Edge Management Gateway...
EMG User Guide - Page 403
...port secureport validatecerts mqttstate mqtthost mqttport mqttsecurity projecttag
Description Configure ConsoleFlow Cloud or On-Premise settings.
set cflow devicename
Syntax set cflow devicename description Description Configure the device name and description used for registration.
set cflow timeoutcli
Syntax set cflow timeoutcli set cflow timeoutdp
EMG™ Edge Management Gateway...
EMG User Guide - Page 469
... support), AU (Australia) and WW (World Mode): set wlan radio region Warning: Each time the region is changed it is programmed into the radio, which can be done a maximum of ~10 times; use care when changing the region. Update the wireless firmware: set wlan update fwfile
dbfile [host ] [login ] [path ] set wlan update reset show wlan [email ]
EMG™ Edge Management Gateway User Guide...