Lantronix EMG 8500 - Edge Management Gateway driver and firmware

Drivers and firmware downloads for this Lantronix item

We have a direct link to download Lantronix EMG 8500 - Edge Management Gateway drivers, firmware and other resources directly from the Lantronix site. To protect our site from spammers you will need to verify you are not a robot below in order to access the download link.

Related Lantronix EMG 8500 - Edge Management Gateway Manual Pages

Download the free PDF manual for Lantronix EMG 8500 - Edge Management Gateway and other Lantronix manuals at ManualOwl.com

EMG Quick Start Guide - Page 1

...Edge Management Gateway ! Thank you for choosing Lantronix. Please register the EMG 8500 in order to receive notifications for firmware and documentation updates at www.lantronix.com/product-registration. WHAT'S IN THE BOX Quick Start Guide START EMG 8500 EMG851210SP with USB and RJ45 FRUs shown. Additional FRU combinations are available. Accessories External Universal AC (100W, 12V) Power...
EMG Quick Start Guide - Page 2

... Guide Edge Management Gateway 4. IP ADDRESSING The EMG 8500 network ports (Ethernet 1 and Ethernet 2) default to DHCP-assigned IP addresses. If you want to assign a different IP address, it must be within a valid range, unique to your network, and on the same subnet as your workstation. Note: You can view the IP address by running the Lantronix Provisioning Manager (LPM) application. Download...
AUS Supplier s Declaration of Conformity: Lantronix EMG8500 - Page 1

... Address (Australian) Unit 308, 469-481 High St Northcote, VIC 3070 OR ACN/ARBN 84156023504 Product details Product description - brand name, type, current model, lot, batch or serial number (if available), software/firmware version (if applicable) Edge Management Gateway, Model EMG8500 (including LTE/4G and Wi-Fi Connectivity Modules). Compliance - applicable standards and other supporting...
EMG User Guide - Page 4

... network path support, with fail-over and fail-back. Note: EMG 8500 firmware cannot be installed on EMG 7500, and vice versa. July 2020 D Updated for firmware release 8.4.0.0R9. It contains the following software changes for EMG 8500 and EMG 7500:  For the cellular modem that acquires the IP address dynamically, if the IP address is configured as the default gateway, fail-over gateway...
EMG User Guide - Page 22

.... Document EMG 8500 Quick Start Guide or EMG 7500 Quick Start Guide EMG 8500 Product Brief or EMG 7500 Product Brief Description Provides accessories and part number information, hardware installation instructions, directions to connect the EMG unit, and network IP configuration information. Provides product overview and specifications. EMGEdge Management Gateway User Guide 22
EMG User Guide - Page 25

... types of IT equipment:  Servers: Unix, Linux, Windows, and others.  Networking equipment: Routers, switches, storage networking.  Telecom: PBX, voice switches.  Other systems with serial interfaces: Heating/cooling systems, security/building access systems, uninterruptible power supply (UPS), medical devices. EMGEdge Management Gateway User Guide 25
EMG User Guide - Page 26

... Protocol Support The EMG supports the following protocols:  TCP/IP network protocol  SSH, TLS, SSL, Telnet and TCP for connections in and out of device ports  DHCP and BOOTP for dynamic IP address assignment  DNS for IP address name resolution  SNMP for remote monitoring and management  SCP, FTP, and SFTP for file transfers and firmware upgrades...
EMG User Guide - Page 64

... Quick Setup page: 1. Open a web browser (Firefox, Chrome or Internet Explorer web browsers with the latest browser updates). 2. In the URL field, type https:// followed by the IP address of your EMG. Note: The web server listens for requests on the unencrypted (HTTP) port (port 80) and redirects all requests to the encrypted (HTTPS) port (port 443). EMGEdge Management Gateway User Guide...
EMG User Guide - Page 89

...the Eth2 Ethernet port only. For internal cellular modems (EMG models only), see Cellular Modem Settings. Select an integrated external device to be used as the fail-over gateway. Currently the Lantronix PW XC HSPA+ Cellular Gateway and the Sierra Wireless ES450 Cellular Gateway are supported. When using an internal cellular modem as the failover gateway, the Fail-over Device should be set to None...
EMG User Guide - Page 91

... depend on the model of the EMG unit. Load Cellular Gateway Firmware Options USB Port The USB Port selection becomes active when you choose to Load Firmware via USB. EMG provides one USB port called U1 in the interface. The firmware files must be stored in the top level directory of the USB flash drive. FTP/SFTP/SCP Server Enter the IP address or host name of the server...
EMG User Guide - Page 93

... Cellular Settings web page allows the user to configure parameters that determine how the EMG cellular modem network behaves, and to update the cellular modem firmware. To complete the Cellular Settings page: 1. Click the Network tab and select the Cellular Modem option. The following page displays: Figure 7-4 Network > Cellular Modem Settings Page EMGEdge Management Gateway User Guide...
EMG User Guide - Page 95

... the APN set to m2m.com.attz and is using DHCP addressing  Current Time: the number of seconds since the modem booted  Temperature: the modem temperature in Celsius  Reset Counter: the number of times the modem has been software reset  Mode: indicates if the modem is online with the cellular network EMGEdge Management Gateway User Guide 95
EMG User Guide - Page 99

...version that is the default firmware for the current EMG release. Updating the firmware or resetting the firmware requires a reboot in order for the change to take effect. To update the WiFi firmware: 1. On the Network > Wireless Settings page, click the Update WiFi Firmware link. The Update WiFi Firmware page appears. Figure 7-5 Update WiFi Firmware EMGEdge Management Gateway User Guide...
EMG User Guide - Page 176

... management of multiple Lantronix ITM devices. A browser based interface (including mobile phone app support) allows an administrator to view status, send commands, view logs and charts and update firmware. Each Lantronix device can communicate with the cloud server or on-premise server, sending status updates and responding to commands sent by the server. An EMG gateway requires a unique Device...
EMG User Guide - Page 177

... a response to the newline character within approximately one second, and this may result in the Device Port Connection Status being set to Disconnected. 8. CLI Commands CLI commands can be issued to a set of EMG from ConsoleFlow. CLI commands which require user input for a confirmation or prompt, or require some other user interaction EMGEdge Management Gateway User Guide 177
EMG User Guide - Page 179

... Eth1 MAC address appended. Long description that is displayed in the ConsoleFlow server UI. The unique device identifier. The ID is 32 alphanumeric characters. The ID may be provisioned using Lantronix Provisioning Manager (LPM). Contact Lantronix Tech Support for more information on LPM. Displays the serial number. Remote Access Idle Timeout Remote Access CLI Timeout Remote Access Device Port...
EMG User Guide - Page 237

..., which will interrupt the power provided by the RPM. Some PDUs and UPSes have a default delay that they will wait before initiating a shutdown; this setting may be visible in the raw data (see above) as "ups.delay.shutdown". Deletes the selected RPM, after a confirmation. Figure 11-2 RPM Shutdown Order EMGEdge Management Gateway User Guide 237
EMG User Guide - Page 252

...enter device port configurations. Right to enter modem settings for USB modems and to control USB storage devices. Right to view and enter settings for SD card. 5. To save, click the Apply button. If the type of script is Interface or Custom, the script will be validated before it is saved. Once the script is saved, the main Devices > Scripts page is displayed. EMGEdge Management Gateway...
EMG User Guide - Page 403

...port secureport validatecerts mqttstate mqtthost mqttport mqttsecurity projecttag Description Configure ConsoleFlow Cloud or On-Premise settings. set cflow devicename Syntax set cflow devicename description Description Configure the device name and description used for registration. set cflow timeoutcli Syntax set cflow timeoutcli set cflow timeoutdp EMGEdge Management Gateway...
EMG User Guide - Page 469

... support), AU (Australia) and WW (World Mode): set wlan radio region Warning: Each time the region is changed it is programmed into the radio, which can be done a maximum of ~10 times; use care when changing the region. Update the wireless firmware: set wlan update fwfile dbfile [host ] [login ] [path ] set wlan update reset show wlan [email ] EMGEdge Management Gateway User Guide...
Get Help Online

Get immediate support for your Lantronix EMG 8500 - Edge Management Gateway questions from HelpOwl.com.

Recent Lantronix EMG 8500 - Edge Management Gateway-related questions:

Lantronix Manuals

Find free Lantronix EMG 8500 - Edge Management Gateway manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Corporate Office

Locate the Lantronix corporate office headquarters phone number, address and more at CorporateOfficeOwl.com.

Contact Information

Complete Lantronix customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Lantronix customer service rankings, employee comments and much more from our sister site.