Lantronix xSenso driver and firmware

Drivers and firmware downloads for this Lantronix item

We have a direct link to download Lantronix xSenso drivers, firmware and other resources directly from the Lantronix site. To protect our site from spammers you will need to verify you are not a robot below in order to access the download link.

Related Lantronix xSenso Manual Pages

Download the free PDF manual for Lantronix xSenso and other Lantronix manuals at ManualOwl.com

xSenso - Product Brief - Page 2

... connection is made. • Configurable Data Acquisition format for selectable network connectivity modes (TCP, UDP, SSL, SSH, TCP-AES) • Configurable Alarms - connect to send streaming data, send email and text message via email • In field firmware upgrades via FTP, HTTP/HTTPS and USB Port > Power* • (1) Terminal screw block • (1) Barrel locking connector Both...
xSenso - Product Brief (A4 Format) - Page 2

... connection is made. • Configurable Data Acquisition format for selectable network connectivity modes (TCP, UDP, SSL, SSH, TCP-AES) • Configurable Alarms - connect to send streaming data, send email and text message via email • In field firmware upgrades via FTP, HTTP/HTTPS and USB Port > Power* • (1) Terminal screw block • (1) Barrel locking connector Both...
xSenso2100 - Quick Start Guide - Page 2

...; Quick Start Guide 4 DEVICE DISCOVERY OVER NETWORK INSTALL DEVICE INSTALLER REQUIREMENTS: Computer must have a working ethernet adapter running Windows as the Operating System (OS). For device discovery, the computer and device should be connected to the same IP subnet. 1. Download the latest version of DeviceInstaller from http://www.lantronix.com/downloads. The minimum required version for...
xSenso21A2 - Quick Start Guide - Page 2

... Both power connectors support an input power source of 9-30VDC. Both may be used simultaneously for power redundancy. 2. C onnect an Ethernet cable between the LAN port on the xSenso™ and a network switch or router. THIS COMPLETES THE HARDWARE INSTALLATION. 4 DEVICE DISCOVERY OVER NETWORK INSTALL DEVICE INSTALLER REQUIREMENTS: Computer must have a working Ethernet adapter running Windows...
xSenso21R2 - Quick Start Guide - Page 2

... Both power connectors support an input power source of 9-30VDC. Both may be used simultaneously for power redundancy. 2. C onnect an Ethernet cable between the LAN port on the xSenso™ and a network switch or router. THIS COMPLETES THE HARDWARE INSTALLATION. 4 DEVICE DISCOVERY OVER NETWORK INSTALL DEVICE INSTALLER REQUIREMENTS: Computer must have a working Ethernet adapter running Windows...
xSenso - User Guide - Page 2

... www.lantronix.com/about/contact. Disclaimer The information in this guide may change without notice. The manufacturer assumes no responsibility for any errors that may appear in this guide. Revision History Date July 2012 March 2013 Rev. A B Comments Initial document for firmware release 7.4.0.0. Updated for firmware release 7.6.0.0R10 and added xSenso 21A2 and xSenso 21R2. xSenso User Guide...
xSenso - User Guide - Page 9

... 117 Security 117 DAQ 118 Software 118 Power 118 Environmental 118 Physical Characteristics 118 Appendix B: Technical Support 119 Appendix C: Binary to Hexadecimal Conversions 120 Converting Binary to Hexadecimal 120 Conversion Table 120 Scientific Calculator 120 Appendix D: Compliance 122 Appendix E: USB-CDC-ACM Device Driver File for Windows Hosts 124 xSenso User Guide 9
xSenso - User Guide - Page 13

... , view statistics, files, and diagnose problems. Instructions for configuring email, CLI and XML settings. Provides additional information on security settings available. Instructions for obtaining the latest firmware and updating the . Instructions on how to brand your device. Technical specifications for the device. Instructions for contacting Lantronix Technical Support. xSenso User Guide 13
xSenso - User Guide - Page 17

... 16 for an explanation of Figure 2-2. Protocol Support The xSenso device server contains a full-featured IP stack. Supported protocols include:  ARP, HTTP, HTTPS...for network communications and management.  TFTP for uploading/downloading files.  FTP and HTTP/HTTPS web server for firmware upgrades and uploading/downloading ...device clock synchronization xSenso User Guide 17
xSenso - User Guide - Page 18

... USB-CDC-ACM connection to the Lantronix device, the driver installation file referenced below needs to be provided when prompted by the Windows Device Driver Installation Wizard. For Windows 7 installation, it is recommended to manually install the driver before plugging in the USB cable to the xSenso device port. This can be done by installing a legacy driver for a COM port, with the Have Disk...
xSenso - User Guide - Page 19

...Lantronix\Device Installer\4.3). b. Follow the instructions inAppendix E: USB-CDC-ACM Device Driver File for Windows Hosts to create the .inf file and follow the windows driver installation steps as outlined above. 2. Connect the USB cable to the MGMT (USB) port of the xSenso device. 3. Connect the USB cable from the xSenso to the USB port on your computer. 4. Apply power. If drivers are installed...
xSenso - User Guide - Page 40

... no BOOTP or DHCP server is found. These addresses are not routable. Accessing xSenso Using DeviceInstaller Note: Make note of the MAC address. It is needed to locate the xSenso using DeviceInstaller. To use the DeviceInstaller utility, first install the latest version from the downloads page on the Lantronix web site www.lantronix.com/downloads. 1. Run the executable to start the...
xSenso - User Guide - Page 41

...xSenso 2100", "xSenso 21A2" or "xSenso 21R2" by default. Long Name Shows Lantronix xSenso 2100", "Lantronix xSenso 21A2" or "Lantronix xSenso 21R2" by default. Type Shows the device type as "xSenso 2100 Series""". ID Shows the xSenso ID embedded within the unit. Hardware Address Shows the xSenso hardware (MAC) address. Firmware Version Shows the firmware currently installed on the xSenso...
xSenso - User Guide - Page 78

... default port is 514. Syslog Settings Table 15-3 Syslog Settings Description State Host Remote Port Select to enable or disable the syslog:  Enabled  Disabled (default) Enter the IP address of the remote server to which system logs are sent for storage. Enter the number of the port on the remote server that supports logging services. The default is 514. xSenso User Guide...
xSenso - User Guide - Page 80

... in some cases where the browser is sending data aggressively within TCP windows size limit, when file (including firmware upgrade) is uploaded from webpage. Logging State Select to enable or disable HTTP server logging:  Enabled (default)  Disabled Max Log Entries Set the maximum number of HTTP server log entries. Only the last...
xSenso - User Guide - Page 101

...xSenso with or without restoring the settings to factory default through the Reset Button on the device. Upload New Firmware Write the new firmware file to firmware.rom on the xSenso. The device automatically reboots upon the installation of new firmware. See the section, FTP Settings... to reboot, restore to factory defaults, upload new firmware, update the system name (long or short names) or ...
xSenso - User Guide - Page 112

20: Updating Firmware Obtaining Firmware Obtain the most up-to-date firmware and release notes for the unit from the Lantronix Web site (www.lantronix.com/support/downloads/) or by using anonymous FTP (ftp://ftp.lantronix.com/). Loading New Firmware through Web Manager Reload the firmware using the device web manager Filesystem page. To upload new firmware: 1. Select the Setup tab/page and click ...
xSenso - User Guide - Page 113

... data aggressively within TCP windows size limit when file (including firmware upgrade) is uploaded from webpage. Loading New Firmware through FTP Firmware may be updated by sending the file to the xSenso over an FTP connection. The destination file name on the xSenso must be "firmware.rom". The device will reboot upon successful completion of the firmware upgrade. Example FTP session: $ ftp...
xSenso - User Guide - Page 118

... connection is made.  Configurable Data Acquisition format for selectable network connectivity modes (TCP, UDP, SSL, SSH, TCP-AES)  Configurable Alarms - connect tsend streaming data, send email and text message via email  In field firmware upgrades via FTP, HTTP/HTTPS and USB Port Power*  (1) Terminal screw block Note: Both terminal screw block and...
xSenso - User Guide - Page 124

... the contents provided below. When Windows prompts for a device driver for the USB connection, point it to this file. Note: For Windows 7 installation, it is recommended to manually install the driver before plugging in the USB cable to the device port. This can be done by installing a legacy driver for a COM port, with the Have Disk... option. ; Windows USB CDC ACM Setup File ; Based on INF...
Get Help Online

Get immediate support for your Lantronix xSenso questions from HelpOwl.com.

Recent Lantronix xSenso-related questions:

Lantronix Manuals

Find free Lantronix xSenso manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Corporate Office

Locate the Lantronix corporate office headquarters phone number, address and more at CorporateOfficeOwl.com.

Contact Information

Complete Lantronix customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings