LevelOne GTL-2880 driver and firmware
Related LevelOne GTL-2880 Manual Pages
Download the free PDF manual for LevelOne GTL-2880 and other LevelOne manuals at ManualOwl.com
Datasheet - Page 2
... of GTL-2880/GTL-5280/GTP-2880/GTL-1072 UPnP s-Flow Event / Error Log / Syslog LLDP IPv6 feature: - IPv6 host mode - IPv6 stateless address auto-configuration - Duplicate address detection (DAD) - ICMP version6 - IPv6 QoS Prioritize IPv6 packets in hardware Green Ethernet IEEE 802.3az Energy Efficient function: Automatically turns off Ethernet port when detecting link down or Idle of client Cable...
Datasheet - Page 3
...
- 24 Gigabit Ethernet ports with 4 shared SFP slots and 4 10 Gigabit SFP plus slots
- Single IP management supports up to 32 switches (GTL-2880/ GTL-5280/GTL-1072/GTP-2880)
- Easy Configuration Port (ECP) for easy deployment of network devices such as IP phone or network camera
- Managed and deployed at IPv6 network operation - IEEE 802.1X port-based authentication with Access Control
List (ACL...
Datasheet - Page 4
...
L2 Managed GE 5
Order Information Package Contents
GTL-2880: L2 Plus Managed Switch - 24 GE with 4 Combo SFP + 4 10GE SFP Plus
GTL-2880 Power Cord Rackmount Kit RS-232 Console Cable CD Manual QIG (Quick Install Guide)
Optional Accessories
GVT-0300 1.25Gbps SFP Transceiver,... are subject to change without notice. © Copyright Digital Data Communications GmbH. All Rights Reserved.
V1.0
Manual - Page 2
... for any software, firmware, information or memory data contained in, stored on or integrated with any Product returned to LevelOne pursuant to any warranty.
EXCLUSIONS. The warranty as mentioned above does not apply to the following conditions, in LevelOne's judgment, it contains (1) customer does not comply with the manual instructions offered by LevelOne in installation, operation, repair...
Manual - Page 3
... Software, which (1) customer does not comply with the manual instructions offered by LevelOne in installation, operation, or maintenance, (2) Product fails due to damage from unusual external or electrical stress, shipment, storage,...any reason, Licensee shall discontinue to use the Software and shall destroy or return all copies of the Software and the related documentation.
GENERAL. This License ...
Manual - Page 6
... Radius Details...219
4-7 PORT SECURITY ...220 4-7.1 Limit Control...220 4-7.2 Switch Status ...223 4-7.3 Port Status...225
4-8 ACCESS MANAGEMENT ...226 4-8.1 Configuration...226 4-8.2 Statistics ...228
4-9 SSH ...229 4-10 HTTPS ...230 4-11 AUTH METHOD ...231
CHAPTER 5.
MAINTENANCE ...232
5-1 RESTART DEVICE ...232 5-2 FIRMWARE ...233
5-2.1 Firmware Upgrade ...233 5-2.2 Firmware Selection ...234...
Manual - Page 9
INTRODUCTION
Overview
In this user's manual, it will not only tell you how to install and connect your network system but configure and monitor the GTL-2880 by (RS-232) serial interface or through the web and Ethernet ports step-by-step. Many explanations in detail of hardware and software functions are shown as well as the examples of the...
Manual - Page 15
...Device Name", "System Up Time", "BIOS Version", "Firmware Version", "Hardware-Mechanical Version", "Serial Number", "Host IP Address", "Host Mac Address", "Device Port", "RAM Size" , "Flash Size" and. With this information, you will know the software version used, MAC address, serial number, how many ports... System Information (GTL-2880 for example, others model the same)
Parameter description:
7
Manual - Page 16
....
Host IP address: The IP address of the switch.
Host MAC address: It is the Ethernet MAC address of the management agent in this switch.
Device Port: Show all types and numbers of the port in the switch.
RAM size: The size of the RAM in this switch.
Flash size: The size of the flash memory in this switch.
...
Manual - Page 18
... time of writing, Microsoft Internet Explorer will need to have a plugin installed to support SVG. For SVG download web site. http://www.adobe.com/svg/viewer/install/ Web interface To configure System Information in the web interface: 1. Click System, System Information, CPU Load . 2. Display the CPU Load on the screen 3. Click Auto-refresh . Figure 2-1.3: CPU Load
Parameter description: ...
Manual - Page 21
...and updated NTP time to come out the local time, otherwise, you will not able to get the correct time. The switch supports configurable...manual parameters. 3. Click Save.
Figure 2-2.2: The NTP configuration
Parameter description: Server 1to 5 : Provide the NTP IPv4 or IPv6 address of this switch. IPv6 address is in 128-bit records represented as eight fields of up to four hexadecimal digits...
Manual - Page 23
...control of the device. But others value need to refer to each group privilege level. User's privilege should be same or greater than the group privilege level to have the access of that group. By default setting..., most groups privilege level 5 has the read-only access and privilege level 10 has the read-write access. And the system maintenance (software upload, factory defaults...
Manual - Page 25
..., System Access Management, Port (contains Dot1x port, MAC based and the MAC Address Limit), ACL, HTTPS, SSH, ARP Inspection and IP source guard. IP: Everything except 'ping'. Port: Everything except 'VeriPHY'. Diagnostics: 'ping' and 'VeriPHY'. Maintenance: System Reboot, System Restore Default, System Password, Configuration Save, Configuration Load and Firmware Load. Web- Users, Privilege...
Manual - Page 29
... logging program messages . It allows separation of the software that generates messages from the system that stores them and the software that reports and analyzes them. It can be used as well a generalized informational, analysis and debugging messages. It is supported by a wide variety of devices and receivers across multiple platforms.
2-5.1 Configuration
This section...
Manual - Page 32
...supported MIB OIDs, including RMON MIB, can be accessed via SNMP manager. If the field SNMP is set "Disable", SNMP agent will be de-activated, the related Community Name, Trap Host IP Address... information of the target device. So, both parties must have the same community name. Once completing the setting, click button, the setting takes effect.
Web Interface
To display the configure SNMP System ...
Manual - Page 124
... are configured by the network administrator if the administrator wants to do a fixed mapping between the DMAC address and switch ports. The frames also contain a MAC address (SMAC address ), which shows the MAC address of the equipment sending the frame. The SMAC address is used by the switch to automatically update the MAC table with these dynamic MAC addresses. Dynamic entries are removed...
Manual - Page 213
... special supplicant software to authenticate. The disadvantage is that MAC addresses can be spoofed by malicious users - equipment whose MAC address is a valid RADIUS user can be used by anyone. Also, only the MD5Challenge method is supported. The maximum number of clients that can be attached to a port can be limited using the Port Security Limit Control functionality.
...
Manual - Page 240
Chapter 5.
Maintenance
This chapter describes the entire switch Maintenance configuration tasks to enhance the performance of local network including Restart Device, Firmware upgrade, Save/Restore, Import/Export, and Diagnostics.
5-1 Restart Device
This section describes how to restart switch for any maintenance needs. Any configuration files or scripts that you saved in the switch should still ...
Manual - Page 241
... with more value-added functions by installing firmware upgrades.
5-2.1 Firmware Upgrade
This page facilitates an update of the firmware controlling the Switch.
Web Interface
To configure a Firmware Upgrade Configuration in the web interface: 1. Chick Browser to select firmware in you device. 2. Click Upload.
Figure 5-2.1: The Firmware update
Parameter description: Browse : Click the...
Manual - Page 256
... are configured by the network administrator if the administrator wants to do a fixed mapping between the DMAC address and switch ports.
The frames also contain a MAC address ( SMAC address ), which shows the MAC address of the equipment sending the frame. The SMAC address is used by the switch to automatically update the MAC table with these dynamic MAC addresses. Dynamic entries are removed...