Intel SR1680MV - Server System - 0 MB RAM driver and firmware
Drivers and firmware downloads for this Intel item
Related Intel SR1680MV Manual Pages
Download the free PDF manual for Intel SR1680MV and other Intel manuals at ManualOwl.com
Service Guide - Page 3
..., upgrading, and repairing this server system. This document provides a brief overview of the board features, a list of accessories or other components you may need, troubleshooting information, and instructions on how to add and replace components on the Intel® Server System SR1680MV. For the latest version of this manual, see http://support.intel.com/support/motherboards/server/SR1680MV...
Service Guide - Page 4
...for your server:
Processor, memory DIMMs, hard drive, and operating system.
For information about which accessories, memory, processors, and third-party hardware were tested and can be used with your board, and for ordering information for Intel products, see http://support.intel.com/support/motherboards/server/SR1680MV/compat.htm.
Additional Information and Software
Documentation and software for...
Service Guide - Page 5
..., including BIOS settings and chipset information
If you just received this product and need to install it
Accessories or other Intel server products
Hardware (peripheral boards, adapter cards, and so forth) and operating systems that were tested with this product
Processors that were tested with this product
DIMMs that were tested with this product
For drivers
For firmware and BIOS updates
To...
Service Guide - Page 9
... devices and cables: Hazardous electrical conditions may be present on power, telephone, and communication cables. Turn off the server and disconnect the power cord, telecommunications systems, networks, and modems attached to the server before opening it. Otherwise, personal injury or equipment damage can result.
Electrostatic discharge (ESD) and ESD protection: ESD can damage disk drives, boards...
Service Guide - Page 11
... Removing the Mid-Top Cover 11 Central Processing Unit (CPU 12 Removing the Processor 13 Installing the Processor 15 Removing the Heatsink 16 Installing the Heatsink 17 System Memory ...17
System Memory Channel Population Requirements for Memory RAS Modes 19 Independent Channel Mode 19 Mirrored Channel Mode 19 Lockstep Channel Mode 19
Intel® Server System SR1680MV Service Guide
xi
Service Guide - Page 12
... Server Board 47 Connector and Component Locations of IO Board 49 Connector and Component Locations of NIC Board 50 Connectors and Components of Front Panel 51 10 GB IO Card (Optional Daughter Card 52 InfiniBand Card (Optional Daughter Card 53 Connector and Component Locations of HDD Backplane 54 Connectors and Component Locations of PDB 55
xii
Intel® Server System SR1680MV Service...
Service Guide - Page 13
... View BMC System Event Log Submenu 83 Remote Access Configuration Submenu 84 Boot Menu ...85 Boot Setting Configuration Submenu 86 Boot Device Priority Submenu 88 Removable Drives Submenu 89 CD/DVD Drives Submenu 90 Security Menu ...91 Trusted Computing Submenu 93 Exit Menu ...95 BIOS Updates ...96 ROM Flash ...96
Chapter 6: Embedded SATA RAID 99
Enabling RAID in the BIOS Setup 99
Chapter...
Service Guide - Page 19
... Table 35. Boot Device Priority Submenu 88 Table 36. Removable Drives Submenu 89 Table 37. CD/DVD Drives Submenu 90 Table 38. Security Menu of BIOS Setup Utility 91 Table 39. Security Menu Fields 92 Table 40. Trusted Computing Submenu 93 Table 41. Trusted Computing Submenu Fields 94 Table 42. Exit Menu of BIOS Setup Utility 95
Intel® Server System SR1680MV Service Guide
xix
Service Guide - Page 21
... manual.
Note: Except where indicated, all descriptions are based on one server board.
Note: The minimum configuration of the server system is to install the right server board. You can only access the power supply when the right server board is installed. The corresponding I/O board must be fixed to the server board when powering on the system.
Intel® Server System SR1680MV Service Guide...
Service Guide - Page 29
2 Hardware Installations and
Upgrades
Before You Begin
Before working with your server product, pay close attention to "Safety Information".
This document provides instructions for adding and replacing system components. For instructions on replacing components on the server board, such as the processor and memory DIMMs, and PCI-E add-in cards.
In addition, this server is also designed with the ...
Service Guide - Page 31
... the server, see "Power Off".
Removing the Mid-Top Cover
1. Release the screw on the mid-top cover. 2. Press down the locking button along the direction of the arrow. 3. Simultaneously slide the mid-top cover forward in the direction of the arrow using
the traction pad, and then lift it up.
Intel® Server System SR1680MV Service Guide...
Service Guide - Page 119
... of the SATA Software RAID options embedded on the server board. The Intel® SR1680MV server is embedded the Intel® Matrix Storage Manager with support for RAID levels 0, 1 and with drivers to support Microsoft Windows* operating systems.
Enabling RAID in the BIOS Setup
By default, the BIOS does NOT enable RAID support. To enable this feature, you must set an option in the BIOS setup as...
Service Guide - Page 121
...detail instructions of installing rail kit to racks for this server. ...Driver Tape
Cross Point Screwdriver
Slotted Point Screwdriver
There are seven spring screw holes in rail to secure each spring. Spring secured in different spring screw holes can fit to different depths for racks. The locations and the adapt depth for racks are shown below:
Intel® Server System SR1680MV Service Guide...
Service Guide - Page 122
..., a third wire safety grounding conductor is necessary for the rack installation. 2. The equipment rack must provide sufficient airflow to the system to maintain proper cooling.
Procedure: 1. Put the tighten screws2 into the washers. 2. Install the tighten screws2 with washers into the hole of the rails (Recommended Driver Force: 5 lb-in).
102
Intel® Server System SR1680MV Service Guide
Service Guide - Page 127
...
Firmware
In Hot-Swap Bay?
Operating System Information (Example: RedHat* Enterprise Linux, Microsoft* Windows* Server 2003, Service pack 1, OEM CD):
Manufacturer:
Version:
Language version (English, Arabic, Chinese (Simplified)):
Service Pack Level or Kernel Revision:
Distribution (OEM/Retail
Intel® RAID Controller: (Example SRCU42E)
Intel® Server System SR1680MV Service Guide...
Service Guide - Page 128
... version: Has the latest RAID firmware been tried? (Yes/No): RAID driver version: Has the latest RAID driver been tried? (Yes/No): RAID volumes configuration (disks & RAID level): RAID volume use (Boot device/Data Volume): Is BBU (Battery Backup Unit) installed? (Yes/No): BBU part number
Detailed description of issue:
Troubleshooting tried:
108
Intel® Server System SR1680MV Service Guide
Service Guide - Page 131
... are using the latest firmware and files. Firmware upgrades include updates for BIOS, and the baseboard management controller (BMC). See "Additional Information and Software" for a link to the software updates. In addition to the server firmware and files, also update any drivers used for components you have installed in your system, such as video drivers, network drivers, and SCSI drivers.
If you...
Service Guide - Page 132
... the system power cord is plugged into a properly grounded AC outlet.
3. Make sure your video display monitor and keyboard are correctly connected to the system. Turn on the video monitor. Set its brightness and contrast controls to at least two thirds of their maximum ranges (see the documentation supplied with your video display monitor).
112
Intel® Server System SR1680MV Service Guide
Service Guide - Page 135
... are bound. • Make sure the hub port is configured for the same duplex mode as the network
controller.
• Make sure the correct networking software is installed. • If you are directly connecting two servers (without a hub), you will need a crossover
cable.
• Check the network controller LEDs next to the NIC connectors.
Intel® Server System SR1680MV Service Guide
115
Service Guide - Page 195
... Form" to better service the issue.
Intel also offers Channel Program members around-the-clock 24x7 technical phone support on Intel® server boards, server chassis, server RAID controller cards, and Intel® Server Management at http://www.intel.com/reseller/.
You will need to log in to the Reseller site to obtain the 24x7 number.
Intel® Server System SR1680MV Service Guide
175