Intel SR1500 - AXXMINIDIMM DDR-2 RAID Controller Cache Memory driver and firmware
Drivers and firmware downloads for this Intel item
Related Intel SR1500 Manual Pages
Download the free PDF manual for Intel SR1500 and other Intel manuals at ManualOwl.com
SR1500 Chassis TPS - Page 27
...
Cooling Zone CPU1 CPU2
PCI
Power Supply
Description of greatest cooling influence
Primary cooling for CPU1 and memory Primary cooling for hard drive2, CPU2, the MCH, and the low profile PCI cards Primary cooling for hard drive1, Full Height PCI cards, PXH and IOP80333 chipset Primary cooling for hard drive 0, and the power supply module
Revision 1.4
15
Intel order number D31981...
SR1500 Chassis TPS - Page 41
... System SR1500AL TPS
Peripheral and Hard Drive Support
lower power requirements when compared to parallel SCSI. SAS controllers leverage an electrical and physical connection interface that is compatible with Serial ATA technology.
The LSISAS1064E supports the Intel® Embedded RAID Technology II solution, which is a highly integrated, low-cost RAID implementation. The runtime operation of...
SR1500 Chassis TPS - Page 53
... • Processor 1 missing • Temperature (CPU ThermTrip, memory TempHi, critical threshold crossed) • No power good - power fault • Processor configuration error (for instance, processor stepping mismatch)
6.2.2.1
System Status LED - BMC Initialization
When AC power is first applied to the system and 5V-STBY is present, the BMC controller on the server board requires 15...
SR1500 Chassis TPS - Page 58
... • Processor 1 missing • Temperature (CPU ThermTrip, memory TempHi, critical threshold crossed) • No power good - power fault • Processor configuration error (for instance, processor stepping mismatch)
7.1.2.1
System Status LED - BMC Initialization
When AC power is first applied to the system and 5V-STBY is present, the BMC controller on the server board requires 15...
SR1500 Chassis TPS - Page 71
... approvals. Updated product information for configurations can be found on the Intel Server Builder Web site at the following URL: http://channel.intel.com/go/serverbuilder If you do not have access to Intel's Web address, please contact your local Intel representative.
Server chassis (base chassis is provided with power supply and fans) - UL listed.
Server board - you...
SR1500 Chassis TPS - Page 80
... run to load the proper Sensor Data Records for the server chassis onto the server board.
• Make sure the latest system software is loaded on the server. This includes system BIOS, FRUSDR, BMC firmware, and hot-swap controller firmware. The latest system software can be downloaded from
http://support.intel.com/support/motherboards/server/S5000PAL/
68
Revision 1.4
Intel order number D31981...
SR1500 Chassis TPS - Page 83
... Drivers
0xE7h
R
A
A
G
Description
Detecting the presence of the keyboard Enabling the keyboard Clearing keyboard input buffer Instructing keyboard controller to run Self Test (PS2 only)
Resetting the mouse Detecting the mouse Detecting the presence of mouse Enabling the mouse
Resetting fixed media device Disabling fixed media device Detecting presence of a fixed media device (IDE hard drive...
SR1500 Chassis TPS - Page 84
... (PEIM) / Recovery
0x30h
OFF OFF R
R Crisis recovery has been initiated because of a user request
0x31h
OFF OFF R
A Crisis recovery has been initiated by software (corrupt flash)
0x34h
OFF G
R
R Loading crisis recovery capsule
0x35h
OFF G
R
A Handing off control to the crisis recovery capsule
0x3Fh
G
G
A
A Unable to complete crisis recovery.
Revision 1.4
V
Intel order number...
SR1550 Chassis TPS - Page 21
...system consists of air baffles, a CPU air duct, and a tool-less fan module which houses five 56 mm dual rotor system fans. In addition, each power supply module includes a 56 mm ... provides support for a lockable front bezel which prevents unauthorized access to the system control buttons and hard drives. In addition, a chassis intrusion switch is provided allowing server management software to ...
SR1550 Chassis TPS - Page 25
... slot must have the power supply blank installed.
Power supply #2
Power supply #1
Chassis Side Edge
Air Flow
Configuring a single power supply module in the #2 module slot will cause the server management firmware and BIOS to generate a system error during POST and to the System Event Log and will cause the System Status LED on the control panel to blink...
SR1550 Chassis TPS - Page 34
... built into the fan bracket to prevent service technicians from accidental contact with fan rotors. Each fan within the module is capable of supporting multiple speeds. If the internal ambient temperature of the system exceeds the value programmed into the thermal sensor data record (SDR), the BMC firmware will increase the speed for all...
SR1550 Chassis TPS - Page 55
...to it an Intel IOP80333 IO processor and an LSI* LSLSAS1068 3Gb/s SAS controller. Together they provide support for up to eight SAS drives in this system. By default, this mid-plane option provides software RAID levels 0, 1, and 10 utilizing Intel® Embedded RAID Technology II. With the installation of optional RAID enablement devices, the mid-plane can support hardware RAID levels 0, 1, 5, 10...
SR1550 Chassis TPS - Page 57
...
IOP80333 IO processor
The Intel® 80333 IO processor is a multi-function device that integrates the Intel Xscale® core with intelligent peripherals and two PCIe* to PCI-X* bridges. It will be connected to the server board 's x4 PCIe lane and serve as bridge for PCI-X 133MHz secondary bus. The IOP80333 also includes fully functional RAID support.
6.3.2.4
LSI* LSISAS1068 SAS Controller...
SR1550 Chassis TPS - Page 64
... should light up. In mirrored configuration, when memory mirroring takes place and system loses memory redundancy. This is not covered by (2). Redundancy loss such as power-supply or fan. This does not apply to non-redundant sub-systems. PCI-e link errors CPU failure / disabled - if there are two processors and one of them fails Fan alarm - Fan...
SR1550 Chassis TPS - Page 70
... IERR signal asserted Processor 1 missing Temperature (CPU ThermTrip, memory TempHi, critical
threshold crossed) No power good - power fault Processor configuration error (for instance, processor
stepping mismatch)
8.2.2.1
System Status LED - BMC Initialization
When AC power is first applied to the system and 5V-STBY is present, the BMC controller on the server board requires 30-35...
SR1550 Chassis TPS - Page 71
... the front panel indicates drive activity from the onboard hard disk controllers. The Intel® Server Board S5000PAL also provides a header giving access to this
LED for add-in controllers.
8.2.4
System Identification LED
The blue system identification LED is used to help identify a system for servicing. This is especially useful when the system is installed when in a high...
SR1550 Chassis TPS - Page 76
... IERR signal asserted Processor 1 missing Temperature (CPU ThermTrip, memory TempHi, critical
threshold crossed) No power good - power fault Processor configuration error (for instance, processor
stepping mismatch)
9.1.2.1
System Status LED - BMC Initialization
When AC power is first applied to the system and 5V-STBY is present, the BMC controller on the server board requires 30-35...
SR1550 Chassis TPS - Page 97
... is best to download the latest FRUSDR Utility for your particular server board from the following web site: http://support.intel.com/support/motherboards/server
o To ensure proper cooling of your server, all air ducts must be in place. In addition, all drive bays must be populated with either a drive or a drive blank.
o Processor fans are not supported and are not...
SR1550 Chassis TPS - Page 100
... Drivers
0xE7h
R
A
A
G
Description
Detecting the presence of the keyboard Enabling the keyboard Clearing keyboard input buffer Instructing keyboard controller to run Self Test (PS2 only)
Resetting the mouse Detecting the mouse Detecting the presence of mouse Enabling the mouse
Resetting fixed media device Disabling fixed media device Detecting presence of a fixed media device (IDE hard drive...
SR2500 Chassis TPS - Page 103
... Data Records for this chassis on to the server board. Failure to do so may result in possible false errors being reported to the System Event Log. It is best to download the latest FRUSDR Utility for your particular server board using the Intel® Server Deployment Toolkit or from the following web site: http://support.intel.com/support/motherboards...