HP Model 715/80 - Workstation driver and firmware
Drivers and firmware downloads for this Hewlett-Packard item
Related HP Model 715/80 Manual Pages
Download the free PDF manual for HP Model 715/80 and other HP manuals at ManualOwl.com
Browsable CD Booklet - Page 1
... Core Enhancements (ACE) The Workstation Quality Pack ..... 3 New Features/Functionality ..... 4
Visualize-fxe USB Devices Consolidated NFS Patches Automatic Configuration of Graphics Cards IDE CD-ROM Drives Distributed Single Logical Screen Year 2000 Compliance ..... 6 System Administration Information ..... 6 Updates and Upgrades Using Software Distributor Installing Patches on a System...
Browsable CD Booklet - Page 6
... make your computer Year 2000 compliant, but they are not sufficient; they only update the core operating system to address date-handling problems known at the time we released those patches.
In order to make your systems fully Year 2000 compliant, you may also need to upgrade application software from HP and independent software vendors...
Browsable CD Booklet - Page 7
... need to update many workstations to HP-UX 10.20 and plan to use a cold-install process, you may benefit from using the HP-UX 10.20 Workstation Transition Toolkit. For more information about the Toolkit, visit the following URL:
http://www.software.hp.com/OS_transition/
Using Software Distributor This booklet describes how to load ACE software for HP-UX
10...
Browsable CD Booklet - Page 8
... on the case of loading the ACE software from a CD-ROM. However, most of the instructions also apply to DDS (tape) media or updating from a remote depot across a network. The only difference is the specification of the Source Depot Type.
Installing Patches on a System with ACE Software When the ACE software is loaded on your computer, exercise
caution in applying...
Browsable CD Booklet - Page 10
... HP-UX Workstation Additional Core Enhancements for 10.20 manual for additional information and more detailed instructions.
Cold Installing with ACE Software You can cold install from the Install/Update/Recovery CD-
ROM that is packaged with this booklet. Hereafter, we will refer to this as the ACE install media.
The version of the install utility on the ACE install media will automatically load...
Browsable CD Booklet - Page 13
... already running HP-UX 10.20, you are ready to use
SD-UX to load ACE software on your system.
NOTE The update process for ACE bundles now involves loading software from two CD-ROMs, if you load the Quality Pack. The necessary discs are included in the box with this booklet.
1. Load the Install/Update/Recovery CD-ROM in your drive and mount...
Browsable CD Booklet - Page 15
... "OK" to install the software. 8. Following the install phase, the swinstall command will reboot your workstation. (This is necessary because the ACE bundle contains kernel enhancements.) 9. After your system reboots, you have completed the first stage of updating with the ACE software. Remove the ACE media from the drive and, if you choose to load the Quality...
Browsable CD Booklet - Page 17
... ready to continue, select "OK" to install the Quality Pack. 8. Following the install phase, the swinstall command will reboot your workstation. (This is necessary because the Quality Pack contains kernel patches.) 9. After your system has rebooted, you have finished updating with the ACE software. You can now remove the Support Plus media from the drive.
17
Browsable CD Booklet - Page 20
... HP-UX Documentation
Upgrading from HP-UX 9.x to 10.x p/n B3782-90073
Installing and Updating HP-UX 10.x p/n B2355-90126
Installing and Updating HP-UX Workstation Additional Core Enhancements for 10.20 p/n B3782-90795
Managing HP-UX Software with SD-UX (for HP-UX 10.20) p/n B2355-90107
Support Plus User's Guide p/n B3782-90812
For release notes and white papers on HP-UX 10.20 and ACE software...
HP-UX DMI 2.0 Developer's Guide: HP-UX/HP 9000 Computers, HP-UX Desktop Management Interface - Page 19
Introduction Installing DMI
Installing DMI
In order to use HP's Desktop Management Interface SDK, you must install the following three software packages: 1. swinstall the HP C/ANSI C Developer's Bundle for HP-UX 10.20 or
the aC++ Compiler S800; 2. swinstall the DCE-BPRG fileset from the DCE Programming
Environment and Libraries bundle; 3. Download the DMI SDK from the HP Software Depot ...
System Configuration Repository User's Reference: HP-UX/HP 9000 Computers, Edition 1.2 - Page 35
... of the log entry and by the level of detail.
Dependencies Between Software
managed nodes The Desktop Management Interface for HP-UX product must be installed on managed nodes.
management server The Desktop Management Interface for HP-UX product must be installed and functional before SCR is installed. SCR needs to be installed on the management server.
Reference
35
System Configuration Repository User's Reference: HP-UX/HP 9000 Computers, Edition 1.2 - Page 39
... RISC2.0"
[Processor Load]
1
1
*
[Host Processor Index] -
1
*
[Processor Firmware ID] -
"HP
PA RISC2.0"
*
[Processor Load]
-
1
:
The output describes a processor difference: base node1 is a PA 1.1 single processor model, and target node2 is PA2.0 multi processor model.
View configuration information by time and managed node with the scrviewer command, which lists one set of...
System Configuration Repository User's Reference: HP-UX/HP 9000 Computers, Edition 1.2 - Page 40
...oldest snapshot for each node. These tags are managed by the system and updated whenever data is collected or removed.
User defined tags: These ...set to on (visible) or off (masked). For newly detected MIFs, a filter's extension flag can be set to on (visible) or off (masked).
For example, suppose the software configuration data is not needed, the HP-UX Installed Software...
1GB and 2GB disk drive source software notice (b2908-90601) - Page 1
... requires a patch)
Notes - 1. Diagnostic support is not available for these drives running on HP-UX 9.01.
2. To install 2-GB drives on HP-UX 9.03, you must use a netdist install server. This device cannot be installed as a standalone device. You must install patch PHSS_5776 on the server to recognize these disk drives.
3. The following drives are fully supported at HP-UX 9.05 (all others need...
1GB and 2GB disk drive source software notice (b2908-90601) - Page 2
...:
1. Begin the HP-UX software installation process. At HP-UX 9.0x releases, if the system has
one of the drives listed above installed, the following message appears:
"Note: the destination disk type "disk-drive" was not found in the disk table /etc/disktab. (Press any key to continue.)"
Press any key. The screen displays the following message:
"If model number: "disk-drive", is incorrect...
1GB disk drive user notes (a1658-90690) - Page 1
....
4. Let the software installation process complete. 5. Install the appropriate patch using /etc/update and reboot the system.
1-GB Disk Drive
User Notes
Refer to your workstation owner's guide or your disk drive installation guide for detailed information about installing your disk drive. During the installation procedure, you may have to change the SCSI ID of your disk drive. Refer to the...
2GB disk drive user notes (a1658-90691) - Page 1
....
4. Let the software installation process complete. 5. Install the appropriate patch using /etc/update and reboot the
system.
2-GB Disk Drive User Notes
Refer to your workstation owner's guide or your disk drive installation guide for detailed information about installing your disk drive. During the installation procedure, you may have to change the SCSI ID of your disk drive. Refer to the...
fast wide differential 2GB, 4GB disk drive user notes (a1658-90692) - Page 2
... Let the software installation process complete.
INSTRUCTIONS FOR HP-UX 10.X After you have loaded HP-UX onto the new drive, install the appropriate patches using swinstall and reboot the system.
2- and 4-GB (Fast-Wide-Differential) Disk Drive User Notes
Refer to your workstation owner's guide or your disk drive installation guide for detailed information about installing your disk drive. During...
fast wide differential 2GB, 4GB disk drive user notes (a1658-90709) - Page 1
... Let the software installation process complete.
INSTRUCTIONS FOR HP-UX 10.X After you have loaded HP-UX onto the new drive, install the appropriate patches using swinstall and reboot the system.
2- and 4-GB (Fast-Wide-Differential) Disk Drive User Notes
Refer to your workstation owner's guide or your disk drive installation guide for detailed information about installing your disk drive. During...
hp DDS-2 tape drive user's guide (a1658-90689) - Page 41
... the SCSI-2 devices available to you before you installed the DDS-2 drive is still not listed, contact your service representative. Verifying the System Operation using SupportWave HP-UX uses a diagnostics product called SupportWave. SupportWave contains the Support Tools Manager so that you can verify your system operation. You can access the Support Tools Manager while in a terminal window. If...